Luxaire / AIR-SOURCE HEAT PUMP

HH836E2S11

LX SERIES · source records, page 44

927 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8–9.5BTU/Wh
Cooling capacity31,600–35,000BTU/h

Each efficiency range summarizes published EPA records for HH836E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 927 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19927 / 927
EER2 · BTU/Wh10–12927 / 927
HSPF2 · BTU/Wh8–9.5927 / 927
Cooling capacity · BTU/h31,600–35,000927 / 927
Heating capacity at 47°F / 8.3°C · BTU/h30,000–33,400927 / 927
Heating capacity at 17°F / −8.3°C · BTU/h25,400–29,600927 / 927
Heating capacity at 5°F / −15°C · BTU/h22,200–27,200927 / 927
COP at 5°F / −15°C2–2.1927 / 927
Equipment / loop typeHP - Split System927 / 927
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)927 / 927
Compressor stagingContinuously variable927 / 927
Connected capabilityNo927 / 927

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF36C5ADS2+ furnace: Z9ES100C16SMPS1AHRI reference: 21852187317.008.50270002.00EPA 4643703 →
CTF36C5CDS2+ furnace: TL9E100C20UH11AHRI reference: 21852186917.008.50262002.00EPA 4643707 →
CTF36C5ADS2+ furnace: TL9E100C20UH11AHRI reference: 21852186517.008.50262002.00EPA 4643711 →
CTM36C5CDS2+ furnace: Z9ES100C16SMPS1AHRI reference: 21852160317.008.50268002.00EPA 4643973 →
CTM36C5ADS2+ furnace: Z9ES100C16SMPS1AHRI reference: 21852159917.008.50268002.00EPA 4643977 →
CTM36C5CDS2+ furnace: LP9C080C16MP13AHRI reference: 21852157717.008.50260002.00EPA 4643999 →
CTM36C5CDS2+ furnace: TP9C080C16MP13AHRI reference: 21852157317.008.50260002.00EPA 4644003 →
CTM36C5CDS2+ furnace: TM9V080C16MP12AHRI reference: 21852156917.008.50260002.00EPA 4644007 →
CTM36C5ADS2+ furnace: LP9C080C16MP13AHRI reference: 21852156717.008.50260002.00EPA 4644009 →
CTM36C5ADS2+ furnace: TP9C080C16MP13AHRI reference: 21852156317.008.50260002.00EPA 4644013 →
CTM36C5ADS2+ furnace: TM9V080C16MP12AHRI reference: 21852155917.008.50260002.00EPA 4644017 →
CTM36C5CDS2+ furnace: TL8E100C20UH11AHRI reference: 21852155517.008.50254002.00EPA 4644021 →
CTM36C5ADS2+ furnace: TL8E100C20UH11AHRI reference: 21852155117.008.50254002.00EPA 4644025 →
CTM36C5CDS2+ furnace: TL9E100C20UH11AHRI reference: 21852142717.008.50262002.00EPA 4644149 →
CTM36C5ADS2+ furnace: TL9E100C20UH11AHRI reference: 21852142317.008.50262002.00EPA 4644153 →
CTU36B5XDS2+TXV+ furnace: LP9C060B12MP13AHRI reference: 21852119317.008.50252002.00EPA 4644383 →
CTU36B5XDS2+TXV+ furnace: TP9C060B12MP13AHRI reference: 21852118917.008.50252002.00EPA 4644387 →
CTU36B5XDS2+TXV+ furnace: TM9V060B12MP12AHRI reference: 21852118517.008.50252002.00EPA 4644391 →
CTF36B5CDS2+ furnace: LP9C060B12MP13AHRI reference: 21852118317.008.50252002.00EPA 4644393 →
CTF36B5CDS2+ furnace: TP9C060B12MP13AHRI reference: 21852117917.008.50252002.00EPA 4644397 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →