Lennox / AIR-SOURCE HEAT PUMP

ML14KP1-042-230A**

MERIT ML14KP1 Series · Merit ML14KP1 SERIES · source records, page 4

85 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.5BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity41,000–42,000BTU/h

Each efficiency range summarizes published EPA records for ML14KP1-042-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 85 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.585 / 85
EER2 · BTU/Wh12.5–13.285 / 85
HSPF2 · BTU/Wh7.8–8.285 / 85
Cooling capacity · BTU/h41,000–42,00085 / 85
Heating capacity at 47°F / 8.3°C · BTU/h38,500–40,50085 / 85
Heating capacity at 17°F / −8.3°C · BTU/h24,600–25,80085 / 85
Heating capacity at 5°F / −15°C · BTU/h19,300–20,80085 / 85
COP at 5°F / −15°C2–2.1485 / 85
Equipment / loop typeHP - Split System85 / 85
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)85 / 85
Compressor stagingSingle stage85 / 85
Connected capabilityNo85 / 85

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CK40[C,U]T-48C-**+TDR+ furnace: ML296UH090XV48C*AHRI reference: 21574002615.207.80206002.10EPA 3652524
CK40[C,U]T-48C-**+TDR+ furnace: SL280UH100NV60C*AHRI reference: 21574003115.207.80206002.10EPA 3652528
CK40[C,U]T-48C-**+TDR+ furnace: SL280UH110V60C*AHRI reference: 21574003215.207.80206002.10EPA 3652529
CK40[C,U]T-48C-**+TDR+ furnace: SL280UH110XV60C*AHRI reference: 21574003315.207.80206002.10EPA 3652530
CK40[C,U]T-48C-**+TDR+ furnace: SL297UH080NV48C*AHRI reference: 21574003415.207.80206002.10EPA 3652531
CK40[C,U]T-48C-**+TDR+ furnace: SL297UH080NV60C*AHRI reference: 21574003515.207.80208002.10EPA 3652532
CK40[C,U]T-48C-**+TDR+ furnace: SLP99UH090XV48C*AHRI reference: 21574003715.207.80206002.10EPA 3652533
CK40[C,U]T-48C-**+TDR+ furnace: SLP99UH110XV60C*AHRI reference: 21574003915.207.80206002.10EPA 3652534
CK40[C,U]T-49C-**+TDR+ furnace: EL195UH100NE60C*AHRI reference: 21574004115.207.80197002.04EPA 3652535
CK40[C,U]T-48C-**+TDR+ furnace: ML196UH090XE60C*AHRI reference: 21574002415.207.80206002.10EPA 3652536
CK40[C,U]T-49C-**+TDR+ furnace: SL297UH080NV60C*AHRI reference: 21574007515.207.80199002.06EPA 3652542
CK40[C,U]T-49C-**+TDR+ furnace: SLP99UH090XV36C*AHRI reference: 21574007615.207.80197002.04EPA 3652543
CK40[C,U]T-49C-**+TDR+ furnace: SLP99UH090XV60C*AHRI reference: 21574007815.207.80198002.02EPA 3652545
CK40[C,U]T-49C-**+TDR+ furnace: EL196UH090XE48C*AHRI reference: 21574004215.207.80197002.02EPA 3652556
CK40[C,U]T-49C-**+TDR+ furnace: EL297UH090XE48C*AHRI reference: 21574004715.207.80199002.06EPA 3652561
CK40[C,U]T-49C-**+TDR+ furnace: EL297UH090XV36C*AHRI reference: 21574004815.207.80196002.04EPA 3652562
CK40[C,U]T-49C-**+TDR+ furnace: EL297UH090XV60C*AHRI reference: 21574005015.207.80200002.04EPA 3652563
CK40[C,U]T-49C-**+TDR+ furnace: EL297UH110XV48C*AHRI reference: 21574005215.207.80197002.04EPA 3652565
CK40[C,U]T-49C-**+TDR+ furnace: EL297UH110XV60C*AHRI reference: 21574005315.207.80197002.04EPA 3652567
CK40[C,U]T-49C-**+TDR+ furnace: ML193UH090XE48C*AHRI reference: 21574005915.207.80200002.06EPA 3652572

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →