Lennox / AIR-SOURCE HEAT PUMP

ML14KP1-042-230A**

MERIT ML14KP1 Series · Merit ML14KP1 SERIES · source records, page 3

85 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.5BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity41,000–42,000BTU/h

Each efficiency range summarizes published EPA records for ML14KP1-042-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 85 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.585 / 85
EER2 · BTU/Wh12.5–13.285 / 85
HSPF2 · BTU/Wh7.8–8.285 / 85
Cooling capacity · BTU/h41,000–42,00085 / 85
Heating capacity at 47°F / 8.3°C · BTU/h38,500–40,50085 / 85
Heating capacity at 17°F / −8.3°C · BTU/h24,600–25,80085 / 85
Heating capacity at 5°F / −15°C · BTU/h19,300–20,80085 / 85
COP at 5°F / −15°C2–2.1485 / 85
Equipment / loop typeHP - Split System85 / 85
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)85 / 85
Compressor stagingSingle stage85 / 85
Connected capabilityNo85 / 85

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CK40[C,U]T-49C-**+TDR+ furnace: ML196UH110XE60C*AHRI reference: 21574006515.507.80195002.06EPA 3652579 →
CK40[C,U]T-49C-**+TDR+ furnace: ML296UH110XV60C*AHRI reference: 21574006715.507.80196002.04EPA 3652580 →
CK40[C,U]T-49C-**+TDR+ furnace: SL280UH080NV60C*AHRI reference: 21574006815.507.80194002.06EPA 3652581 →
CK40[C,U]T-49C-**+TDR+ furnace: SL280UH090V60C*AHRI reference: 21574006915.507.80195002.04EPA 3652582 →
CK40[C,U]T-49C-**+TDR+ furnace: SL280UH090XV60C*AHRI reference: 21574007015.507.80195002.04EPA 3652583 →
CK40[C,U]T-49C-**+TDR+ furnace: ML296UH090XV48C*AHRI reference: 21574006615.507.80196002.04EPA 3652584 →
CBK47UHET-048-460-**AHRI reference: 21759543215.508.20204002.14EPA 4480474 →
CK40[C,U]T-49C-**+TDR+ furnace: ML297UH110XV60C*AHRI reference: 21869070315.507.80194002.04EPA 4679267 →
CBK45UHVT-048-230-**AHRI reference: 21573999515.208.00196002.08EPA 3652488 →
CBK48MVT-042-230-**AHRI reference: 21573999815.208.10202002.14EPA 3652491 →
CBK48MVT-048-230-**AHRI reference: 21573999915.208.20204002.14EPA 3652492 →
CK40[C,U]T-48C-**+TDR+ furnace: EL297UH090XE48C*AHRI reference: 21574000715.207.80208002.10EPA 3652509 →
CK40[C,U]T-48C-**+TDR+ furnace: EL297UH090XV36C*AHRI reference: 21574000815.207.80206002.08EPA 3652510 →
CK40[C,U]T-48C-**+TDR+ furnace: EL297UH090XV48C*AHRI reference: 21574000915.207.80206002.10EPA 3652511 →
CK40[C,U]T-48C-**+TDR+ furnace: EL297UH110XE60C*AHRI reference: 21574001115.207.80206002.08EPA 3652512 →
CK40[C,U]T-48C-**+TDR+ furnace: EL297UH110XV48C*AHRI reference: 21574001215.207.80206002.08EPA 3652513 →
CK40[C,U]T-48C-**+TDR+ furnace: EL297UH110XV60C*AHRI reference: 21574001315.207.80206002.08EPA 3652514 →
CK40[C,U]T-48C-**+TDR+ furnace: ML193UH090XE36C*AHRI reference: 21574001815.207.80204002.10EPA 3652519 →
CK40[C,U]T-48C-**+TDR+ furnace: ML193UH110XE60C*AHRI reference: 21574002115.207.80206002.10EPA 3652521 →
CK40[C,U]T-48C-**+TDR+ furnace: ML296UH110XV60C*AHRI reference: 21574002715.207.80206002.10EPA 3652523 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →