Lennox / AIR-SOURCE HEAT PUMP

EL19KPV-036-230A**

Elite EL19KPV SERIES · source records, page 7

154 published source records · source checked Sep 21, 2026

SEER2 range15.5–19BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,200–35,800BTU/h

Each efficiency range summarizes published EPA records for EL19KPV-036-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 154 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–19154 / 154
EER2 · BTU/Wh11–11.5154 / 154
HSPF2 · BTU/Wh7.8–8.5154 / 154
Cooling capacity · BTU/h33,200–35,800154 / 154
Heating capacity at 47°F / 8.3°C · BTU/h31,000–36,000154 / 154
Heating capacity at 17°F / −8.3°C · BTU/h18,400–23,000154 / 154
Heating capacity at 5°F / −15°C · BTU/h14,600–17,700154 / 154
COP at 5°F / −15°C1.9–2.3154 / 154
Equipment / loop typeHP - Split System154 / 154
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)154 / 154
Compressor stagingContinuously variable154 / 154
Connected capabilityNo154 / 154

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CK40HT-36C-**+TDR+ furnace: SL280UH110V60C*AHRI reference: 21719438416.508.00164002.08EPA 4011507
CK40HT-36C-**+TDR+ furnace: SL280UH110XV60C*AHRI reference: 21719438716.508.00164002.08EPA 4011508
CK40HT-36C-**+TDR+ furnace: SLP99UH090XV60C*AHRI reference: 21719440616.508.00165002.06EPA 4011514
CK40HT-36C-**+TDR+ furnace: EL297UH090XE48C*AHRI reference: 21719440716.508.20163002.08EPA 4011515
CK40HT-36C-**+TDR+ furnace: EL297UH090XV60C*AHRI reference: 21719441216.508.00165002.06EPA 4011518
CK40HT-36C-**+TDR+ furnace: EL297UH110XV60C*AHRI reference: 21719441416.508.00165002.06EPA 4011519
CK40DT-30/36C-**+TDR+ furnace: SL280DF090V60C*AHRI reference: 21744674816.508.00165002.10EPA 4045591
CK40DT-30/36C-**+TDR+ furnace: SL280DF110V60C*AHRI reference: 21744675816.508.00165002.12EPA 4045601
CK40DT-30/36C-**+TDR+ furnace: SLP99DF090XV60C*AHRI reference: 21744676016.508.00167002.08EPA 4045603
CK40DT-30/36C-**+TDR+ furnace: SLP99DF110XV60C*AHRI reference: 21744676116.508.00167002.08EPA 4045604
CK40HT-36C-**+TDR+ furnace: ML197UH080XE48C*AHRI reference: 21874770316.508.10173002.04EPA 4705702
CK40[C,U]T-30/36B-**+TDR+ furnace: EL280UH090E48B*AHRI reference: 21719424016.008.00163001.92EPA 4011482
CK40[C,U]T-30/36B-**+TDR+ furnace: EL280UH090XE48B*AHRI reference: 21719424116.008.00163001.92EPA 4011483
CK40[C,U]T-30/36B-**+TDR+ furnace: ML180UH090E48B*AHRI reference: 21719424616.008.00163001.92EPA 4011485
CK40[C,U]T-30/36B-**+TDR+ furnace: ML180UH090XE48B*AHRI reference: 21719424816.008.00163001.92EPA 4011486
CK40[C,U]T-30/36C-**+TDR+ furnace: EL280UH110E48C*AHRI reference: 21719427416.008.00162001.94EPA 4011487
CK40[C,U]T-30/36C-**+TDR+ furnace: ML193UH110XE48C*AHRI reference: 21719428516.008.10163001.92EPA 4011489
CK40HT-36C-**+TDR+ furnace: ML180UH110E60C*AHRI reference: 21719435016.008.10164002.08EPA 4011494
CK40HT-36C-**+TDR+ furnace: ML180UH110XE60C*AHRI reference: 21719435716.008.10164002.08EPA 4011496
CK40DT-30/36C-**+TDR+ furnace: EL297DF090XE48C*AHRI reference: 21744675016.008.00164002.10EPA 4045593

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →