SEER2 range15.5–19BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,200–35,800BTU/h

Each efficiency range summarizes published EPA records for EL19KPV-036-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 154 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–19154 / 154
EER2 · BTU/Wh11–11.5154 / 154
HSPF2 · BTU/Wh7.8–8.5154 / 154
Cooling capacity · BTU/h33,200–35,800154 / 154
Heating capacity at 47°F / 8.3°C · BTU/h31,000–36,000154 / 154
Heating capacity at 17°F / −8.3°C · BTU/h18,400–23,000154 / 154
Heating capacity at 5°F / −15°C · BTU/h14,600–17,700154 / 154
COP at 5°F / −15°C1.9–2.3154 / 154
Equipment / loop typeHP - Split System154 / 154
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)154 / 154
Compressor stagingContinuously variable154 / 154
Connected capabilityNo154 / 154

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CK40HT-36C-**+TDR+ furnace: EL297UH110XV48C*AHRI reference: 21719441317.008.00165002.06EPA 4011517 →
CK40DT-30/36C-**+TDR+ furnace: SLP99DF090XV36C*AHRI reference: 21744675917.008.10167002.08EPA 4045602 →
CK40HT-36C-**+TDR+ furnace: ML193UH045XE36B*AHRI reference: 21750759017.008.20164002.04EPA 4469623 →
CK40HT-36C-**+TDR+ furnace: ML193UH070XE36B*AHRI reference: 21750759117.008.20163002.06EPA 4469624 →
CK40HT-42C-**+TDR+ furnace: EL280UH110E48C*AHRI reference: 21750759217.008.20163002.10EPA 4469625 →
CK40HT-42C-**+TDR+ furnace: ML193UH110XE48C*AHRI reference: 21750759417.008.20164002.08EPA 4469627 →
CK40HT-42C-**+TDR+ furnace: ML180UH090E48B*AHRI reference: 21750759917.008.20163002.08EPA 4469632 →
CK40HT-36C-**+TDR+ furnace: EL195UH060NE36B*AHRI reference: 21750762417.008.20163002.06EPA 4480459 →
CK40[C,U]T-36C-**+TDR+ furnace: ML193UH090XE48C*AHRI reference: 21807389817.008.20147001.94EPA 4577724 →
CK40[C,U]T-36C-**+TDR+ furnace: ML196UH090XE48C*AHRI reference: 21807386917.008.20147001.94EPA 4577748 →
CK40[C,U]T-36C-**+TDR+ furnace: EL196UH090XE48C*AHRI reference: 21807385717.008.20147001.94EPA 4577760 →
CK40HT-36C-**+TDR+ furnace: ML297UH090XV36C*AHRI reference: 21869510417.007.80173002.02EPA 4691602 →
CK40HT-36C-**+TDR+ furnace: ML197UH060XE36B*AHRI reference: 21874772517.008.10170002.04EPA 4705680 →
CK40[C,U]T-36C-**+TDR+ furnace: ML197UH080XE48C*AHRI reference: 21874770217.008.20151001.98EPA 4705703 →
CK40[C,U]T-36B-**+TDR+ furnace: EL180UH080NE48B*AHRI reference: 21719419716.508.20148001.92EPA 4011431 →
CK40HT-36C-**+TDR+ furnace: EL196UH090XE48C*AHRI reference: 21719433716.508.20163002.08EPA 4011492 →
CK40HT-36C-**+TDR+ furnace: EL280UH110E48C*AHRI reference: 21719434216.508.20161002.10EPA 4011493 →
CK40HT-36C-**+TDR+ furnace: ML193UH090XE48C*AHRI reference: 21719436316.508.20162002.08EPA 4011498 →
CK40HT-36C-**+TDR+ furnace: ML193UH110XE48C*AHRI reference: 21719436616.508.20162002.08EPA 4011499 →
CK40HT-36C-**+TDR+ furnace: ML196UH090XE48C*AHRI reference: 21719436916.508.20163002.08EPA 4011500 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.