Lennox / AIR-SOURCE HEAT PUMP

EL19KPV-024-230A**

Elite EL19KPV SERIES · source records, page 6

221 published source records · source checked Sep 21, 2026

SEER2 range15.2–20BTU/Wh
HSPF2 range7.8–9BTU/Wh
Cooling capacity21,600–24,000BTU/h

Each efficiency range summarizes published EPA records for EL19KPV-024-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 221 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–20221 / 221
EER2 · BTU/Wh11–13.4221 / 221
HSPF2 · BTU/Wh7.8–9221 / 221
Cooling capacity · BTU/h21,600–24,000221 / 221
Heating capacity at 47°F / 8.3°C · BTU/h22,800–25,600221 / 221
Heating capacity at 17°F / −8.3°C · BTU/h13,300–17,000221 / 221
Heating capacity at 5°F / −15°C · BTU/h11,700–17,000221 / 221
COP at 5°F / −15°C1.48–2.04221 / 221
Equipment / loop typeHP - Split System221 / 221
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)221 / 221
Compressor stagingContinuously variable221 / 221
Connected capabilityNo221 / 221

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CK40[C,U]T-36B-**+TDR+ furnace: ML297UH070XV36B*AHRI reference: 21869069519.008.50119001.72EPA 4679271
CK40[C,U]T-36B-**+TDR+ furnace: ML297UH045XV36B*AHRI reference: 21869067119.008.50120001.70EPA 4679283
CK40[C,U]T-30B-**+TDR+ furnace: ML297UH045XV36B*AHRI reference: 21869067019.008.10139001.88EPA 4679284
CK40[C,U]T-24B-**+TDR+ furnace: ML297UH045XV36B*AHRI reference: 21869066919.008.50165002.00EPA 4679285
CK40[C,U]T-36B-**+TDR+ furnace: ML197UH030XE36B*AHRI reference: 21874506019.007.80117001.70EPA 4705668
CK40[C,U]T-30B-**+TDR+ furnace: ML197UH030XE36B*AHRI reference: 21874505919.008.20137001.86EPA 4705669
CK40[C,U]T-24B-**+TDR+ furnace: ML197UH030XE36B*AHRI reference: 21874505819.008.50162001.98EPA 4705670
CK40[C,U]T-36B-**+TDR+ furnace: ML180UH070E36B*AHRI reference: 21719414018.508.50151001.90EPA 4011066
CK40[C,U]T-36B-**+TDR+ furnace: ML180UH070XE36B*AHRI reference: 21719414318.508.50151001.90EPA 4011069
CK40[C,U]T-36B-**+TDR+ furnace: SL280UH080NV48B*AHRI reference: 21719415318.508.50152001.88EPA 4011079
CK40[C,U]T-36B-**+TDR+ furnace: SL280UH090V48B*AHRI reference: 21719415518.508.50151001.88EPA 4011080
CK40[C,U]T-36B-**+TDR+ furnace: SL280UH090XV48B*AHRI reference: 21719415618.508.50151001.88EPA 4011082
CK40[C,U]T-36B-**+TDR+ furnace: EL297UH070XV36B*AHRI reference: 21719416518.508.50152001.88EPA 4011090
CK40[C,U]T-36B-**+TDR+ furnace: EL297UH045XV36B*AHRI reference: 21719416418.508.50153001.88EPA 4011091
CK40[C,U]T-36A-**+TDR+ furnace: ML180UH045E36A*AHRI reference: 21719417318.508.50150001.86EPA 4011099
CK40[C,U]T-36A-**+TDR+ furnace: ML180UH045XE36A*AHRI reference: 21719417518.508.50150001.86EPA 4011101
CBK47UHET-030-230-**AHRI reference: 21719464418.508.50156002.04EPA 4011109
CBK48MVT-018/024-230-**AHRI reference: 21719412918.508.00143001.80EPA 4011458
CK40[C,U]T-24B-**+TDR+ furnace: EL196UH070XE36B*AHRI reference: 21744684118.508.50165002.04EPA 4045439
CK40[C,U]T-24B-**+TDR+ furnace: ML180UH070E36B*AHRI reference: 21744684318.508.50163002.02EPA 4045441