Lennox / AIR-SOURCE HEAT PUMP

EL19KPV-024-230A**

Elite EL19KPV SERIES · source records, page 5

221 published source records · source checked Sep 21, 2026

SEER2 range15.2–20BTU/Wh
HSPF2 range7.8–9BTU/Wh
Cooling capacity21,600–24,000BTU/h

Each efficiency range summarizes published EPA records for EL19KPV-024-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 221 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–20221 / 221
EER2 · BTU/Wh11–13.4221 / 221
HSPF2 · BTU/Wh7.8–9221 / 221
Cooling capacity · BTU/h21,600–24,000221 / 221
Heating capacity at 47°F / 8.3°C · BTU/h22,800–25,600221 / 221
Heating capacity at 17°F / −8.3°C · BTU/h13,300–17,000221 / 221
Heating capacity at 5°F / −15°C · BTU/h11,700–17,000221 / 221
COP at 5°F / −15°C1.48–2.04221 / 221
Equipment / loop typeHP - Split System221 / 221
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)221 / 221
Compressor stagingContinuously variable221 / 221
Connected capabilityNo221 / 221

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CK40[C,U]T-24A-**+TDR+ furnace: SL280UH060NV36A*AHRI reference: 21744688419.008.50164002.02EPA 4045482 →
CK40[C,U]T-30B-**+TDR+ furnace: EL280UH090E36B*AHRI reference: 21744689219.008.20136001.86EPA 4045490 →
CK40[C,U]T-30B-**+TDR+ furnace: ML193UH045XE36B*AHRI reference: 21744690119.008.20141001.88EPA 4045499 →
CK40[C,U]T-30B-**+TDR+ furnace: ML193UH070XE36B*AHRI reference: 21744690219.008.20140001.88EPA 4045500 →
CK40[C,U]T-30B-**+TDR+ furnace: ML196UH030XE36B*AHRI reference: 21744690319.008.10137001.84EPA 4045501 →
CK40[C,U]T-30B-**+TDR+ furnace: ML296UH045XV36B*AHRI reference: 21744691319.008.10138001.88EPA 4045511 →
CK40[C,U]T-30B-**+TDR+ furnace: SL280UH080NV48B*AHRI reference: 21744691619.008.10139001.86EPA 4045514 →
CK40[C,U]T-30B-**+TDR+ furnace: SL280UH090V48B*AHRI reference: 21744691919.008.10138001.90EPA 4045517 →
CK40[C,U]T-30B-**+TDR+ furnace: SL280UH090XV48B*AHRI reference: 21744692219.008.10138001.90EPA 4045520 →
CK40[C,U]T-30B-**+TDR+ furnace: SL297UH060NV36B*AHRI reference: 21744692519.008.10139001.86EPA 4045523 →
CK40[C,U]T-30B-**+TDR+ furnace: EL280UH070E36A*AHRI reference: 21744693019.008.20141001.88EPA 4045528 →
CK40[C,U]T-30B-**+TDR+ furnace: EL297UH045XV36B*AHRI reference: 21744693919.008.10139001.86EPA 4045614 →
CK40[C,U]T-30A-**+TDR+ furnace: EL180UH040NE36A*AHRI reference: 21744695019.008.20140001.88EPA 4045625 →
CK40[C,U]T-30A-**+TDR+ furnace: EL180UH060NE36A*AHRI reference: 21744695119.008.20140001.88EPA 4045626 →
CK40[C,U]T-30A-**+TDR+ furnace: EL280UH070E36A*AHRI reference: 21744695319.008.20141001.88EPA 4045628 →
CK40[C,U]T-30A-**+TDR+ furnace: EL280UH070XE36A*AHRI reference: 21744695519.008.20141001.88EPA 4045630 →
CK40[C,U]T-30A-**+TDR+ furnace: ML180UH045E36A*AHRI reference: 21744695919.008.20137001.86EPA 4045634 →
CK40[C,U]T-30A-**+TDR+ furnace: ML180UH045XE36A*AHRI reference: 21744696419.008.20137001.86EPA 4045639 →
CK40[C,U]T-30A-**+TDR+ furnace: SL280UH070V36A*AHRI reference: 21744697019.008.10139001.88EPA 4045645 →
CK40[C,U]T-30A-**+TDR+ furnace: SL280UH070XV36A*AHRI reference: 21744697119.008.10139001.88EPA 4045646 →