EL17XP1-036-230A**
ELITE EL17XP1 SERIES · ELITE EL17XP1 Series · Elite EL17XP1 Series · source records, page 5
603 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for EL17XP1-036-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 603 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16.8 | 603 / 603 |
| EER2 · BTU/Wh | 12.2–13.5 | 603 / 603 |
| HSPF2 · BTU/Wh | 7.8–8.7 | 603 / 603 |
| Cooling capacity · BTU/h | 34,800–36,000 | 603 / 603 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 32,400–36,000 | 603 / 603 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 21,400–24,000 | 603 / 603 |
| Heating capacity at 5°F / −15°C · BTU/h | 16,800–19,300 | 603 / 603 |
| COP at 5°F / −15°C | 2.06–2.36 | 603 / 603 |
| Equipment / loop type | HP - Split System | 603 / 603 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 603 / 603 |
| Compressor staging | Single stage | 603 / 603 |
| Connected capability | No | 603 / 603 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CHX35-42C-**-*+TDR+ furnace: SLP99UH090XV48C*AHRI reference: 211001805 | 16.40 | 8.00 | 18000 | 2.20 | EPA 2468825 → |
CHX35-42C-**-*+TDR+ furnace: EL297UH090XV48C*AHRI reference: 213194685 | 16.40 | 8.00 | 18000 | 2.20 | EPA 2633337 → |
CHX35-42C-**-*+TDR+ furnace: EL297UH090XE48C*AHRI reference: 213630245 | 16.40 | 8.00 | 17900 | 2.22 | EPA 2836296 → |
CRX35-48C-**-*+TDR+ furnace: SL280DF110V60C*AHRI reference: 213257806 | 16.40 | 8.70 | 19100 | 2.34 | EPA 2839547 → |
CHX35-42C-**-*+TDR+ furnace: EL297UH110XE60C*AHRI reference: 213434219 | 16.40 | 8.00 | 17800 | 2.20 | EPA 2842231 → |
CK40DT-48C-0*+TDR+ furnace: SL280DF110V60C*AHRI reference: 214622600 | 16.40 | 8.70 | 19100 | 2.34 | EPA 3473979 → |
CK40CT-36B-0*+TDR+ furnace: EL280UH090E36B*AHRI reference: 214622626 | 16.40 | 7.80 | 17000 | 2.14 | EPA 3474028 → |
CK40CT-36B-0*+TDR+ furnace: EL280UH090E48B*AHRI reference: 214622627 | 16.40 | 7.80 | 17000 | 2.14 | EPA 3474033 → |
CK40CT-36B-0*+TDR+ furnace: EL280UH090XE48B*AHRI reference: 214622628 | 16.40 | 7.80 | 17000 | 2.14 | EPA 3474034 → |
CK40CT-36B-0*+TDR+ furnace: ML180UH070V48B*AHRI reference: 214622635 | 16.40 | 8.00 | 17200 | 2.18 | EPA 3474420 → |
CK40CT-36B-0*+TDR+ furnace: SL280UH080NV48B*AHRI reference: 214622646 | 16.40 | 8.00 | 17000 | 2.16 | EPA 3474445 → |
CK40CT-36B-0*+TDR+ furnace: SL280UH090V36B*AHRI reference: 214622647 | 16.40 | 7.80 | 17200 | 2.18 | EPA 3474451 → |
CK40CT-50/60C-0*+TDR+ furnace: EL280UH110E48C*AHRI reference: 214622658 | 16.40 | 7.80 | 17000 | 2.12 | EPA 3474485 → |
CK40CT-50/60C-0*+TDR+ furnace: EL280UH110E60C*AHRI reference: 214622659 | 16.40 | 7.80 | 17100 | 2.16 | EPA 3474486 → |
CK40CT-50/60C-0*+TDR+ furnace: EL280UH110XE60C*AHRI reference: 214622660 | 16.40 | 7.80 | 17100 | 2.16 | EPA 3474487 → |
CK40CT-50/60C-0*+TDR+ furnace: ML180UH090E60C*AHRI reference: 214622668 | 16.40 | 7.80 | 17000 | 2.12 | EPA 3474499 → |
CK40CT-50/60C-0*+TDR+ furnace: ML180UH110V60C*AHRI reference: 214622670 | 16.40 | 8.00 | 17200 | 2.14 | EPA 3474501 → |
CK40CT-50/60C-0*+TDR+ furnace: SL280UH080NV60C*AHRI reference: 214622681 | 16.40 | 8.00 | 17200 | 2.14 | EPA 3474764 → |
CK40HT-42B-0*+TDR+ furnace: ML180UH090E48B*AHRI reference: 214622426 | 16.40 | 8.10 | 18300 | 2.28 | EPA 3475961 → |
CK40HT-42B-0*+TDR+ furnace: SL280UH080NV48B*AHRI reference: 214622436 | 16.40 | 8.10 | 18400 | 2.28 | EPA 3476407 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →