Lennox / AIR-SOURCE HEAT PUMP

EL17XP1-036-230A**

ELITE EL17XP1 SERIES · ELITE EL17XP1 Series · Elite EL17XP1 Series · source records, page 4

603 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity34,800–36,000BTU/h

Each efficiency range summarizes published EPA records for EL17XP1-036-230A**. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 603 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8603 / 603
EER2 · BTU/Wh12.2–13.5603 / 603
HSPF2 · BTU/Wh7.8–8.7603 / 603
Cooling capacity · BTU/h34,800–36,000603 / 603
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000603 / 603
Heating capacity at 17°F / −8.3°C · BTU/h21,400–24,000603 / 603
Heating capacity at 5°F / −15°C · BTU/h16,800–19,300603 / 603
COP at 5°F / −15°C2.06–2.36603 / 603
Equipment / loop typeHP - Split System603 / 603
Refrigerant / source-reported GWPR-410A (GWP:2088)603 / 603
Compressor stagingSingle stage603 / 603
Connected capabilityNo603 / 603

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CX35-50/60C+TDR+ furnace: ML180UH090E60C*AHRI reference: 21029368516.407.80170002.12EPA 2460825 →
CHX35-51/61C-**-*+TDR+ furnace: ML193UH110XE48C*AHRI reference: 21029357016.407.80174002.18EPA 2460826 →
CX35-36B+TDR+ furnace: SL280UH090V36B*AHRI reference: 21029366516.407.80172002.18EPA 2460830 →
CX35-50/60C+TDR+ furnace: EL280UH110E60C*AHRI reference: 21029367616.407.80171002.16EPA 2460867 →
C35-50/60C+TDR+TXV+ furnace: EL280UH110E48C*AHRI reference: 21029341016.407.80170002.12EPA 2460873 →
C35-50/60C+TDR+TXV+ furnace: EL280UH110XE60C*AHRI reference: 21029341216.407.80171002.16EPA 2460875 →
C35-36B+TDR+TXV+ furnace: ML180UH070V48B*AHRI reference: 21029338816.408.00172002.18EPA 2461087 →
CHX35-51/61C-**-*+TDR+ furnace: SL280UH100NV60C*AHRI reference: 21029358116.408.10178002.22EPA 2461090 →
C35-36B+TDR+TXV+ furnace: EL280UH090E36B*AHRI reference: 21029337916.407.80170002.14EPA 2462063 →
C35-36B+TDR+TXV+ furnace: SL280UH090V36B*AHRI reference: 21029340016.407.80172002.18EPA 2462075 →
C35-50/60C+TDR+TXV+ furnace: EL280UH110E60C*AHRI reference: 21029341116.407.80171002.16EPA 2462084 →
C35-36B+TDR+TXV+ furnace: EL280UH090XE48B*AHRI reference: 21029338116.407.80170002.14EPA 2462325 →
CX35-36B+TDR+ furnace: ML180UH070V48B*AHRI reference: 21029365316.408.00172002.18EPA 2462365 →
CHX35-42C-**-*+TDR+ furnace: EL195UH100NE60C*AHRI reference: 21100177016.408.00178002.18EPA 2468803 →
CHX35-42C-**-*+TDR+ furnace: EL196UH090XE48C*AHRI reference: 21100177116.408.00181002.20EPA 2468806 →
CHX35-42C-**-*+TDR+ furnace: ML180UH090E60C*AHRI reference: 21100178316.408.00179002.20EPA 2468812 →
CHX35-42C-**-*+TDR+ furnace: ML193UH110XE60C*AHRI reference: 21100178916.408.00179002.18EPA 2468816 →
CHX35-42C-**-*+TDR+ furnace: ML196UH090XE60C*AHRI reference: 21100179216.408.00179002.18EPA 2468817 →
CHX35-42C-**-*+TDR+ furnace: ML196UH090XE48C*AHRI reference: 21100179116.408.00181002.20EPA 2468818 →
CHX35-42C-**-*+TDR+ furnace: ML193UH090XE48C*AHRI reference: 21100178716.408.00179002.20EPA 2468819 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.