Kenmore / AIR-SOURCE HEAT PUMP

XH548E2S11*

LX SERIES · source records, page 2

149 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity45,500–48,000BTU/h

Each efficiency range summarizes published EPA records for XH548E2S11*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 149 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16149 / 149
EER2 · BTU/Wh11–12149 / 149
HSPF2 · BTU/Wh7.8–8.1149 / 149
Cooling capacity · BTU/h45,500–48,000149 / 149
Heating capacity at 47°F / 8.3°C · BTU/h45,000–48,000149 / 149
Heating capacity at 17°F / −8.3°C · BTU/h29,200–32,200149 / 149
Heating capacity at 5°F / −15°C · BTU/h24,600–27,000149 / 149
COP at 5°F / −15°C2.1–2.42149 / 149
Equipment / loop typeHP - Split System149 / 149
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)149 / 149
Compressor stagingTwo-stage149 / 149
Connected capabilityNo149 / 149

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM60C5CGS1+ furnace: Z8VT100C20SMPC1AHRI reference: 21744506015.207.80258002.26EPA 4570495
CTF60D5CGS1+JME18D2SN1AHRI reference: 21694202115.207.80250002.26EPA 4570700
CTF60C5CGS1+JME16C2SN1AHRI reference: 21694187115.207.80250002.26EPA 4570701
JHE48D5CG2SS1AHRI reference: 21694148915.207.80246002.26EPA 4570703
CTF60C5CHS1+ furnace: Z9ET100C20SMPS1AHRI reference: 21694146115.207.80264002.34EPA 4570704
CTM60D5CGS1+JME18D2SN1AHRI reference: 21694117615.207.80254002.30EPA 4570705
JHE48C5CG2SS1AHRI reference: 21694110015.207.80248002.10EPA 4570706
CTF60C5CHS1+ furnace: Z9ET100C16SMPS1AHRI reference: 21694098315.207.80266002.34EPA 4570709
CTF60C5CHS1+JME12C2SN1AHRI reference: 21694081515.207.80258002.40EPA 4570710
CTM60C5CGS1+JME16C2SN1AHRI reference: 21694080615.207.80254002.30EPA 4570711
JHC48C5CG2SS1AHRI reference: 21694065715.207.80248002.26EPA 4570712
CTF60C5CHS1+ furnace: Z9ET080C16SMPS1AHRI reference: 21694061015.207.80262002.34EPA 4570714
JSE48D5CG2SS1AHRI reference: 21694047915.207.80246002.26EPA 4570715
JHC48D5CG2SS1AHRI reference: 21694047615.207.80248002.26EPA 4570716
JHE60C5CH2SS2AHRI reference: 21845731715.208.10264002.40EPA 4639414
JHE48C5CG2SS2AHRI reference: 21845731615.207.80248002.10EPA 4639415
JHE60D5CH2SS2AHRI reference: 21845731515.208.10262002.42EPA 4639416
JHE48D5CG2SS2AHRI reference: 21845731415.207.80246002.26EPA 4639417
CTM60D5CHS2+JMC20D2SN1AHRI reference: 21859952915.208.10262002.42EPA 4652031
CTM60D5CHS2+ furnace: Z8ES130D20LMPS1*AHRI reference: 21859952815.208.10264002.40EPA 4652032

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →