XH548E2S11*
LX SERIES
149 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH548E2S11*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 149 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 149 / 149 |
| EER2 · BTU/Wh | 11–12 | 149 / 149 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 149 / 149 |
| Cooling capacity · BTU/h | 45,500–48,000 | 149 / 149 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 45,000–48,000 | 149 / 149 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–32,200 | 149 / 149 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,600–27,000 | 149 / 149 |
| COP at 5°F / −15°C | 2.1–2.42 | 149 / 149 |
| Equipment / loop type | HP - Split System | 149 / 149 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 149 / 149 |
| Compressor staging | Two-stage | 149 / 149 |
| Connected capability | No | 149 / 149 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM60C5CHS1+ furnace: Z8VT100C16SMPC1AHRI reference: 217445078 | 16.00 | 7.80 | 26200 | 2.38 | EPA 4570483 → |
CTF60C5CHS1+ furnace: Z8VT120C20SMPC1AHRI reference: 217445076 | 16.00 | 7.80 | 26400 | 2.40 | EPA 4570485 → |
CTM60C5CHS1+ furnace: Z8VT080C16SMPC1AHRI reference: 217445075 | 16.00 | 7.80 | 26200 | 2.38 | EPA 4570486 → |
CTM60C5CHS1+ furnace: Z8VT120C20SMPC1AHRI reference: 217445073 | 16.00 | 7.80 | 26000 | 2.42 | EPA 4570488 → |
CTM60C5CHS1+ furnace: Z8VT100C20SMPC1AHRI reference: 217445072 | 16.00 | 7.80 | 26400 | 2.40 | EPA 4570489 → |
CTM60C5CHS2+ furnace: Z8VT100C16SMPC1AHRI reference: 218599520 | 16.00 | 7.80 | 26200 | 2.38 | EPA 4652038 → |
CTM60C5CHS2+ furnace: Z8VT120C20SMPC1AHRI reference: 218599519 | 16.00 | 7.80 | 26000 | 2.42 | EPA 4652039 → |
CTM60C5CHS2+ furnace: Z8VT100C20SMPC1AHRI reference: 218599518 | 16.00 | 7.80 | 26400 | 2.40 | EPA 4652040 → |
CTM60C5CHS2+ furnace: Z8VT080C16SMPC1AHRI reference: 218599517 | 16.00 | 7.80 | 26200 | 2.38 | EPA 4652041 → |
CTF60C5CHS2+ furnace: Z8VT120C20SMPC1AHRI reference: 218599427 | 16.00 | 7.80 | 26400 | 2.40 | EPA 4652116 → |
JHE60C5CH2SS1AHRI reference: 216940873 | 15.20 | 8.10 | 26400 | 2.40 | EPA 4498102 → |
JHE60D5CH2SS1AHRI reference: 216941109 | 15.20 | 8.10 | 26200 | 2.42 | EPA 4498122 → |
CTF60C5CHS1+ furnace: Z8VT080C16SMPC1AHRI reference: 217445079 | 15.20 | 7.80 | 26200 | 2.38 | EPA 4570482 → |
CTF60C5CHS1+ furnace: Z8VT100C16SMPC1AHRI reference: 217445077 | 15.20 | 7.80 | 26200 | 2.38 | EPA 4570484 → |
CTF60C5CHS1+ furnace: Z8VT100C20SMPC1AHRI reference: 217445074 | 15.20 | 7.80 | 26400 | 2.40 | EPA 4570487 → |
CTU60C5XGS1+TXV+ furnace: Z8VT120C20SMPC1AHRI reference: 217445070 | 15.20 | 7.80 | 25600 | 2.28 | EPA 4570490 → |
CTF60C5CGS1+ furnace: Z8VT120C20SMPC1AHRI reference: 217445069 | 15.20 | 7.80 | 25600 | 2.28 | EPA 4570491 → |
CTM60C5CGS1+ furnace: Z8VT120C20SMPC1AHRI reference: 217445063 | 15.20 | 7.80 | 25600 | 2.28 | EPA 4570492 → |
CTU60C5XGS1+TXV+ furnace: Z8VT100C20SMPC1AHRI reference: 217445062 | 15.20 | 7.80 | 25800 | 2.26 | EPA 4570493 → |
CTF60C5CGS1+ furnace: Z8VT100C20SMPC1AHRI reference: 217445061 | 15.20 | 7.80 | 25800 | 2.26 | EPA 4570494 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →