Kenmore / AIR-SOURCE HEAT PUMP

N5H8T24*K*AAA*

2-STAGE 18 SEER HP · source records, page 12

512 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 512 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5512 / 512
EER2 · BTU/Wh11.5–14512 / 512
HSPF2 · BTU/Wh7.8–8.5512 / 512
Cooling capacity · BTU/h22,200–25,000512 / 512
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400512 / 512
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000512 / 512
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500512 / 512
COP at 5°F / −15°C1.9–2.24512 / 512
Equipment / loop typeHP - Split System512 / 512
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)512 / 512
Compressor stagingTwo-stage512 / 512
Connected capabilityNo512 / 512

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X25M17A*+ furnace: *80CSU0401712B*AHRI reference: 21572042017.008.00110002.10EPA 3980238
EA*5X25M17A*+ furnace: *97CTN0601716A*AHRI reference: 21572044817.008.00111002.08EPA 3980274
EA*5X30M17A*+ furnace: *97CTN0801716A*AHRI reference: 21572055417.008.00110002.06EPA 3980922
EA*5X30M17A*+ furnace: *97VTN0801716A*AHRI reference: 21572058917.008.00110002.06EPA 3980958
EA*5X36M17A*+ furnace: *80CSU0401712B*AHRI reference: 21572060417.008.00109002.06EPA 3980971
EA*5X36M17A*+ furnace: *80CSU0601716B*AHRI reference: 21572061817.007.80109002.08EPA 3980984
EA*5X36M17A*+ furnace: *97CTN0801716A*AHRI reference: 21572064617.008.00110002.06EPA 3981011
EA*5X36M17A*+ furnace: *97VTN0601716A*AHRI reference: 21572066317.008.00110002.06EPA 3981172
EA*5X36M17A*+ furnace: *97VTN0801716A*AHRI reference: 21572068117.008.00109002.06EPA 3981189
EA*5X37M17A*+ furnace: *80CSU0401712B*AHRI reference: 21572069617.008.00110002.08EPA 3981206
EA*5X37M17A*+ furnace: *80CSU0601716B*AHRI reference: 21572071017.008.00110002.10EPA 3981219
EA*5X37M17A*+ furnace: *97CTN0601716A*AHRI reference: 21572072417.008.00111002.08EPA 3981294
EA*5X37M17A*+ furnace: *97VTN0601716A*AHRI reference: 21572075517.008.00111002.08EPA 3981324
EA*5X37M17A*+ furnace: *97VTN0801716A*AHRI reference: 21572077317.008.00111002.08EPA 3981343
EA*5X37M21A*+ furnace: *80CSU0401712B*AHRI reference: 21572078817.008.00111002.12EPA 3981362
EA*5X37M21A*+ furnace: *80CSU0601716B*AHRI reference: 21572080217.008.00111002.10EPA 3981375
EA*5X37M21A*+ furnace: *80CSU1002120B*AHRI reference: 21572083017.008.00111002.08EPA 3981398
EA*5X37M17A*+ furnace: *97VTN0601412A*AHRI reference: 21799145317.008.00111002.08EPA 4566405
EA*5X25M17A*+ furnace: *97VTN0601412A*AHRI reference: 21799138917.008.00112002.08EPA 4566495
EA*5X37M21A*+ furnace: *97VTN0401712A*AHRI reference: 21799159717.008.00114002.06EPA 4566592

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →