Kenmore / AIR-SOURCE HEAT PUMP

N5H8T24*K*AAA*

2-STAGE 18 SEER HP · source records, page 11

512 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 512 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5512 / 512
EER2 · BTU/Wh11.5–14512 / 512
HSPF2 · BTU/Wh7.8–8.5512 / 512
Cooling capacity · BTU/h22,200–25,000512 / 512
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400512 / 512
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000512 / 512
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500512 / 512
COP at 5°F / −15°C1.9–2.24512 / 512
Equipment / loop typeHP - Split System512 / 512
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)512 / 512
Compressor stagingTwo-stage512 / 512
Connected capabilityNo512 / 512

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X37M17A*+ furnace: *96VTN0601716B*AHRI reference: 21564764717.008.10111002.08EPA 3960091 →
EA*5X37M17A*+ furnace: OLV098A12*AHRI reference: 21564769817.008.10111002.08EPA 3960124 →
EA*5X37M17A*+ furnace: OMV098J12*AHRI reference: 21564772017.008.10111002.08EPA 3960130 →
EA*5X37M17A*+ furnace: OMV112K14AAHRI reference: 21564774117.008.10115002.04EPA 3960149 →
EA*5X37M17A*+ furnace: *96VSN0601412B*AHRI reference: 21564738917.008.10111002.08EPA 3960337 →
EA*5X37M17A*+ furnace: *96VSN0601716B*AHRI reference: 21564740717.008.10111002.08EPA 3960343 →
EA*5X37M17A*+ furnace: *95MSU0401712A*AHRI reference: 21564744917.007.80111002.08EPA 3960376 →
EA*5X37M17A*+ furnace: *95MSU0601716A*AHRI reference: 21564747617.007.80110002.10EPA 3960384 →
EA*5X37M21A*+ furnace: *96VTN0401712B*AHRI reference: 21564863617.008.10114002.06EPA 3961098 →
EA*5X37M21A*+ furnace: *96VSN0401712B*AHRI reference: 21564833017.008.10114002.06EPA 3961401 →
EA*5X37M21A*+ furnace: OLV098A12*AHRI reference: 21564877517.008.10115002.04EPA 3961743 →
ESH5X36M12A*+ furnace: *80MSU0802120A*AHRI reference: 21565198417.007.80110002.10EPA 3964053 →
ESH5X36M12A*+ furnace: *80CTL0701412B*AHRI reference: 21565205517.007.80110002.08EPA 3964068 →
ESH5X36M12A*+ furnace: *80VTL1102122B*AHRI reference: 21565231117.007.80111002.08EPA 3964178 →
ESH5X36M12A*+ furnace: *80CSU0401712A*AHRI reference: 21565176617.008.10111002.08EPA 3964490 →
ESH5X36M12A*+ furnace: *80VSL1102122B*AHRI reference: 21565188317.007.80110002.08EPA 3964657 →
ESH5X36M12A*+ furnace: *95MSU1002122A*AHRI reference: 21565279617.007.80110002.08EPA 3965087 →
ESH5X36M12A*+ furnace: *96VTN1002122B*AHRI reference: 21565312917.007.80109002.10EPA 3965197 →
ESH5X36M12A*+ furnace: *96VSN1202422B*AHRI reference: 21565266517.008.00110002.08EPA 3965612 →
ESH5X36M12A*+ furnace: *95MSU1002120A*AHRI reference: 21565277317.007.80110002.08EPA 3965644 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →