Kenmore / AIR-SOURCE HEAT PUMP

HH836E2S11*

LX SERIES · source records, page 17

381 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8.1–9.5BTU/Wh
Cooling capacity31,600–35,000BTU/h

Each efficiency range summarizes published EPA records for HH836E2S11*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 381 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19381 / 381
EER2 · BTU/Wh10–12381 / 381
HSPF2 · BTU/Wh8.1–9.5381 / 381
Cooling capacity · BTU/h31,600–35,000381 / 381
Heating capacity at 47°F / 8.3°C · BTU/h30,000–33,000381 / 381
Heating capacity at 17°F / −8.3°C · BTU/h25,400–29,600381 / 381
Heating capacity at 5°F / −15°C · BTU/h22,200–27,200381 / 381
COP at 5°F / −15°C2–2.1381 / 381
Equipment / loop typeHP - Split System381 / 381
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)381 / 381
Compressor stagingContinuously variable381 / 381
Connected capabilityNo381 / 381

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM36C5ADS2+ furnace: Z9ES080C20SMPS1*AHRI reference: 21859997618.008.50264002.00EPA 4651742 →
CTM36C5CDS2+ furnace: Z8ES120C20LMPS1*AHRI reference: 21859997518.008.50262002.00EPA 4651743 →
CTM36C5CDS2+ furnace: Z8ES120C20SMPS1*AHRI reference: 21859997418.008.50262002.00EPA 4651744 →
CTM36C5ADS2+ furnace: Z8ES120C20LMPS1*AHRI reference: 21859997318.008.50262002.00EPA 4651745 →
CTM36C5ADS2+ furnace: Z8ES120C20SMPS1*AHRI reference: 21859997218.008.50262002.00EPA 4651746 →
CTM36C5CDS2+ furnace: Z8ES100C16LMPS1*AHRI reference: 21859997118.008.50260002.00EPA 4651747 →
CTM36C5CDS2+ furnace: Z8ES100C16SMPS1*AHRI reference: 21859997018.008.50260002.00EPA 4651748 →
CTM36C5ADS2+ furnace: Z8ES100C16LMPS1*AHRI reference: 21859996918.008.50260002.00EPA 4651749 →
CTM36C5ADS2+ furnace: Z8ES100C16SMPS1*AHRI reference: 21859996818.008.50260002.00EPA 4651750 →
CTM36C5CDS2+ furnace: Z8ES100C20SMPS1*AHRI reference: 21859996718.008.50262002.00EPA 4651751 →
CTM36C5CDS2+ furnace: Z8ES100C20LMPS1*AHRI reference: 21859996618.008.50262002.00EPA 4651752 →
CTM36C5ADS2+ furnace: Z8ES100C20LMPS1*AHRI reference: 21859996518.008.50262002.00EPA 4651753 →
CTM36C5ADS2+ furnace: Z8ES100C20SMPS1*AHRI reference: 21859996418.008.50262002.00EPA 4651754 →
CTM36C5CDS2+ furnace: Z8VT100C20SMPC1AHRI reference: 21859994918.008.50230002.00EPA 4651769 →
CTM36C5ADS2+ furnace: Z8VT100C20SMPC1AHRI reference: 21859994818.008.50230002.00EPA 4651770 →
CTM36C5CDS2+ furnace: Z8VT100C16SMPC1AHRI reference: 21859994318.008.50232002.00EPA 4651775 →
CTM36C5ADS2+ furnace: Z8VT100C16SMPC1AHRI reference: 21859994218.008.50232002.00EPA 4651776 →
CTU36B5XDS2+TXV+ furnace: Z8VT080B12SMPC1AHRI reference: 21859993818.009.00228002.00EPA 4651780 →
CTF36B5CDS2+ furnace: Z8VT080B12SMPC1AHRI reference: 21859993718.009.00228002.00EPA 4651781 →
CTF36B5ADS2+ furnace: Z8VT080B12SMPC1AHRI reference: 21859993618.009.00228002.00EPA 4651782 →