Kenmore / AIR-SOURCE HEAT PUMP

HH836E2S11*

LX SERIES · source records, page 16

381 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8.1–9.5BTU/Wh
Cooling capacity31,600–35,000BTU/h

Each efficiency range summarizes published EPA records for HH836E2S11*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 381 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19381 / 381
EER2 · BTU/Wh10–12381 / 381
HSPF2 · BTU/Wh8.1–9.5381 / 381
Cooling capacity · BTU/h31,600–35,000381 / 381
Heating capacity at 47°F / 8.3°C · BTU/h30,000–33,000381 / 381
Heating capacity at 17°F / −8.3°C · BTU/h25,400–29,600381 / 381
Heating capacity at 5°F / −15°C · BTU/h22,200–27,200381 / 381
COP at 5°F / −15°C2–2.1381 / 381
Equipment / loop typeHP - Split System381 / 381
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)381 / 381
Compressor stagingContinuously variable381 / 381
Connected capabilityNo381 / 381

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF36C5ADS2+ furnace: Z8VT100C20SMPC1AHRI reference: 21860005418.009.00230002.00EPA 4651664 →
CTM48C5CFS2+ furnace: Z9ES100C16SMPS1*AHRI reference: 21860003318.009.00258002.00EPA 4651685 →
CTM48C5AFS2+ furnace: Z9ES100C16SMPS1*AHRI reference: 21860003218.009.00258002.00EPA 4651686 →
CTM36C5CDS2+ furnace: Z9ET080C16SMPS1AHRI reference: 21859999518.008.50236002.00EPA 4651723 →
CTM36C5ADS2+ furnace: Z9ET080C16SMPS1AHRI reference: 21859999418.008.50236002.00EPA 4651724 →
CTM36C5CDS2+ furnace: Z8ES080C20SMPS1*AHRI reference: 21859999118.008.50262002.00EPA 4651727 →
CTM36C5ADS2+ furnace: Z8ES080C20LMPS1*AHRI reference: 21859999018.008.50262002.00EPA 4651728 →
CTM36C5ADS2+ furnace: Z8ES080C20SMPS1*AHRI reference: 21859998918.008.50262002.00EPA 4651729 →
CTM36C5CDS2+ furnace: Z8ES080C16LMPS1*AHRI reference: 21859998818.008.50254002.00EPA 4651730 →
CTM36C5CDS2+ furnace: Z8ES080C16SMPS1*AHRI reference: 21859998718.008.50254002.00EPA 4651731 →
CTM36C5CDS2+ furnace: Z8ES080C20LMPS1*AHRI reference: 21859998618.008.50262002.00EPA 4651732 →
CTM36C5ADS2+ furnace: Z8ES080C16LMPS1*AHRI reference: 21859998518.008.50254002.00EPA 4651733 →
CTM36C5ADS2+ furnace: Z8ES080C16SMPS1*AHRI reference: 21859998418.008.50254002.00EPA 4651734 →
CTM36C5CDS2+ furnace: Z9ES080C16SMPS1*AHRI reference: 21859998318.008.50254002.00EPA 4651735 →
CTM36C5ADS2+ furnace: Z9ES080C16SMPS1*AHRI reference: 21859998218.008.50254002.00EPA 4651736 →
CTM36C5CDS2+ furnace: Z8ES120C16LMPS1*AHRI reference: 21859998118.008.50258002.00EPA 4651737 →
CTM36C5CDS2+ furnace: Z8ES120C16SMPS1*AHRI reference: 21859998018.008.50258002.00EPA 4651738 →
CTM36C5ADS2+ furnace: Z8ES120C16LMPS1*AHRI reference: 21859997918.008.50258002.00EPA 4651739 →
CTM36C5ADS2+ furnace: Z8ES120C16SMPS1*AHRI reference: 21859997818.008.50258002.00EPA 4651740 →
CTM36C5CDS2+ furnace: Z9ES080C20SMPS1*AHRI reference: 21859997718.008.50264002.00EPA 4651741 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →