Kenmore / AIR-SOURCE HEAT PUMP

(C,H,T)5H8T24*K*AAA*

Mainline 18 SEER2 HP · source records, page 3

496 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for (C,H,T)5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 496 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5496 / 496
EER2 · BTU/Wh11.7–14496 / 496
HSPF2 · BTU/Wh7.8–8.5496 / 496
Cooling capacity · BTU/h22,200–25,000496 / 496
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400496 / 496
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000496 / 496
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500496 / 496
COP at 5°F / −15°C1.94–2.24496 / 496
Equipment / loop typeHP - Split System496 / 496
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)496 / 496
Compressor stagingTwo-stage496 / 496
Connected capabilityNo496 / 496

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X37M21A*+ furnace: *80MSU0802120A*AHRI reference: 21636646218.008.50111002.24EPA 3811570
EA*5X37M21A*+ furnace: *80VTL0701716B*AHRI reference: 21636652618.008.10111002.12EPA 3812180
EA*5X37M21A*+ furnace: *80VTL1102122B*AHRI reference: 21636654218.008.50112002.22EPA 3812196
EA*5X37M21A*+WALLCON+ furnace: *95CSU1002122B*AHRI reference: 21636656618.008.10112002.12EPA 3812220
EA*5X37M21A*+ furnace: *95MSU1002120A*AHRI reference: 21636667818.008.50112002.22EPA 3812292
EA*5X25M17A*+WALLCON+ furnace: *80CSU0401712B*AHRI reference: 21636517318.008.50112002.22EPA 3812296
EA*5X25M17A*+WALLCON+ furnace: *80CSU0601716B*AHRI reference: 21636518118.008.00112002.10EPA 3812304
EA*5X37M21A*+ furnace: *95MSU1002122A*AHRI reference: 21636668618.008.10111002.14EPA 3812372
EA*5X37M21A*+WALLCON+ furnace: *96CTN1002122B*AHRI reference: 21636671818.008.10112002.12EPA 3812468
EA*5X37M21A*+ furnace: *96VTN0601716B*AHRI reference: 21636673418.008.10112002.10EPA 3812484
EA*5X37M21A*+ furnace: *96VTN0802120B*AHRI reference: 21636675018.008.50112002.22EPA 3812500
EA*5X37M21A*+ furnace: *96VTN1002120B*AHRI reference: 21636675818.008.10111002.12EPA 3812509
EA*5X37M21A*+ furnace: *96VTN1002122B*AHRI reference: 21636676618.008.50112002.22EPA 3812516
EA*5X37M21A*+WALLCON+ furnace: *80CSU0401712A*AHRI reference: 21636639018.008.10112002.12EPA 3812780
FTMA5X24L0B*AHRI reference: 21615278917.508.10111002.08EPA 3802034
EVM5X31M17A*+ furnace: *80VSL0451412B*AHRI reference: 21636116517.507.80109002.06EPA 3807960
EA*5X25M17A*+ furnace: *96VSN0801716B*AHRI reference: 21636506117.508.10111002.10EPA 3809219
EA*5X25M17A*+ furnace: *95MSU0601716A*AHRI reference: 21636507717.508.10111002.12EPA 3809235
FCMA5X24L0B*+WALLCONAHRI reference: 21636891217.508.10111002.08EPA 3809330
EA*5X36M17A*+ furnace: *80VTL0451412B*AHRI reference: 21636571717.508.10109002.10EPA 3809354

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →