Kenmore / AIR-SOURCE HEAT PUMP

(C,H,T)5H8T24*K*AAA*

Mainline 18 SEER2 HP · source records, page 2

496 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for (C,H,T)5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 496 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5496 / 496
EER2 · BTU/Wh11.7–14496 / 496
HSPF2 · BTU/Wh7.8–8.5496 / 496
Cooling capacity · BTU/h22,200–25,000496 / 496
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400496 / 496
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000496 / 496
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500496 / 496
COP at 5°F / −15°C1.94–2.24496 / 496
Equipment / loop typeHP - Split System496 / 496
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)496 / 496
Compressor stagingTwo-stage496 / 496
Connected capabilityNo496 / 496

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X37M21A*+WALLCON+ furnace: *80CSU0601716B*AHRI reference: 21636680618.008.10112002.12EPA 3809688
EA*5X37M21A*+WALLCON+ furnace: *80CSU0802120B*AHRI reference: 21636681418.008.50112002.24EPA 3809696
EA*5X37M21A*+ furnace: *97VTN0802120A*AHRI reference: 21636687818.008.50112002.22EPA 3810008
EA*5X37M21A*+ furnace: *97VTN1002122A*AHRI reference: 21636689418.008.50112002.22EPA 3810024
EA*5X25M17A*+ furnace: *80MSU0401712A*AHRI reference: 21636494118.008.10111002.12EPA 3810234
EA*5X25M17A*+ furnace: *80VSL0701412B*AHRI reference: 21636491718.008.10110002.12EPA 3810386
EA*5X25M17A*+ furnace: *80VSL0701716B*AHRI reference: 21636492518.008.10111002.12EPA 3810430
EA*5X25M17A*+WALLCON+ furnace: *80CSU0401712A*AHRI reference: 21636489318.008.10112002.12EPA 3810435
EA*5X37M21A*+WALLCON+ furnace: *97CTN1002122A*AHRI reference: 21636685418.008.10112002.12EPA 3810748
EA*5X37M21A*+WALLCON+ furnace: *80CTL0901716B*AHRI reference: 21636650218.008.10112002.12EPA 3810883
EA*5X37M21A*+WALLCON+ furnace: *80CTL0902120B*AHRI reference: 21636651018.008.10112002.12EPA 3810891
EA*5X37M21A*+WALLCON+ furnace: *80CTL1102120B*AHRI reference: 21636651818.008.10112002.12EPA 3810899
EA*5X37M21A*+WALLCON+ furnace: *80CSU0601716A*AHRI reference: 21636639818.008.10112002.12EPA 3810989
EA*5X37M21A*+ furnace: *80VSL0901716B*AHRI reference: 21636642218.008.10111002.12EPA 3811013
EA*5X37M21A*+ furnace: *80VSL1102122B*AHRI reference: 21636643818.008.50111002.22EPA 3811029
EA*5X37M21A*+ furnace: *80MSU0401712A*AHRI reference: 21636644618.008.50111002.24EPA 3811037
EA*5X37M21A*+ furnace: *80MSU0601716A*AHRI reference: 21636645418.008.50112002.24EPA 3811044
EVD5X38M17A*+ furnace: *96VSN0601716B*AHRI reference: 21636428518.007.80111002.04EPA 3811248
EVD5X38M17A*+ furnace: *96VTN0601716B*AHRI reference: 21636434118.007.80111002.04EPA 3811451
EVD5X38M17A*+ furnace: OMV112K14AAHRI reference: 21636436518.007.80112002.02EPA 3811460

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.