(C,H,T)5H0V48*K*AAA*
Deluxe 20 VS Heat Pump · source records, page 11
376 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for (C,H,T)5H0V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 376 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 376 / 376 |
| EER2 · BTU/Wh | 9–10.5 | 376 / 376 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 376 / 376 |
| Cooling capacity · BTU/h | 43,500–49,000 | 376 / 376 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 376 / 376 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 376 / 376 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 376 / 376 |
| COP at 5°F / −15°C | 1.92–2.2 | 376 / 376 |
| Equipment / loop type | HP - Split System | 376 / 376 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 376 / 376 |
| Compressor staging | Continuously variable | 376 / 376 |
| Connected capability | No | 376 / 376 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X61M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215681561 | 18.50 | 9.00 | 33600 | 2.06 | EPA 3975277 → |
EA*5X61M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 215681571 | 18.50 | 9.00 | 33600 | 2.06 | EPA 3975284 → |
EVM5X48M21A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 215681781 | 18.50 | 9.00 | 36200 | 2.00 | EPA 3975575 → |
EVM5X48M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215681811 | 18.50 | 9.00 | 36400 | 2.00 | EPA 3975745 → |
EVM5X49M21A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 215681831 | 18.50 | 9.00 | 36600 | 2.00 | EPA 3975763 → |
EVM5X49M21A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 215681841 | 18.50 | 9.00 | 36800 | 2.00 | EPA 3975770 → |
EVM5X49M21A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 215681861 | 18.50 | 9.00 | 36600 | 2.00 | EPA 3975786 → |
EVM5X49M21A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 215681871 | 18.50 | 9.00 | 37200 | 1.98 | EPA 3976009 → |
EVD5X48M21A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 215682161 | 18.50 | 9.00 | 36600 | 1.98 | EPA 3976327 → |
EVM5X60M21A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 215681911 | 18.50 | 9.00 | 36600 | 2.00 | EPA 3976363 → |
EVM5X60M21A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 215681921 | 18.50 | 9.00 | 36800 | 2.00 | EPA 3976373 → |
EVM5X60M21A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 215681941 | 18.50 | 9.00 | 36600 | 2.00 | EPA 3976396 → |
EVM5X60M21A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 215681951 | 18.50 | 9.00 | 37200 | 1.98 | EPA 3976402 → |
EVM5X60M24A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 215682001 | 18.50 | 9.00 | 36600 | 2.00 | EPA 3976452 → |
EVD5X48M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215682171 | 18.50 | 9.00 | 36400 | 2.00 | EPA 3976472 → |
EVD5X48M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 215682181 | 18.50 | 9.00 | 36400 | 2.00 | EPA 3976477 → |
EVD5X48M24A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 215682191 | 18.50 | 9.00 | 36000 | 2.02 | EPA 3976492 → |
EVD5X48M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 215682211 | 18.50 | 9.00 | 36400 | 2.00 | EPA 3976525 → |
EVD5X48M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 215682231 | 18.50 | 9.00 | 36400 | 2.00 | EPA 3976533 → |
EVD5X49M24A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 215682261 | 18.50 | 9.00 | 36600 | 2.00 | EPA 3976634 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →