Heating performance & equipment details
Ranges include the 376 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 376 / 376 |
| EER2 · BTU/Wh | 9–10.5 | 376 / 376 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 376 / 376 |
| Cooling capacity · BTU/h | 43,500–49,000 | 376 / 376 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 376 / 376 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 376 / 376 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 376 / 376 |
| COP at 5°F / −15°C | 1.92–2.2 | 376 / 376 |
| Equipment / loop type | HP - Split System | 376 / 376 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 376 / 376 |
| Compressor staging | Continuously variable | 376 / 376 |
| Connected capability | No | 376 / 376 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X48M24A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 215676201 | 18.50 | 9.00 | 36600 | 2.02 | EPA 3969977 → |
EVD5X48M24A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 215676251 | 18.50 | 9.00 | 36200 | 2.02 | EPA 3970103 → |
EVD5X48M24A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 215676261 | 18.50 | 9.00 | 36400 | 2.00 | EPA 3970104 → |
EVD5X48M24A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 215676271 | 18.50 | 9.00 | 36400 | 2.00 | EPA 3970125 → |
EVD5X48M24A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 215676281 | 18.50 | 9.00 | 36400 | 2.00 | EPA 3970137 → |
EVD5X49M24A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 215676351 | 18.50 | 9.00 | 37000 | 1.98 | EPA 3970207 → |
EVD5X60M24A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 215676661 | 18.50 | 9.00 | 37000 | 1.98 | EPA 3970264 → |
EVD5X61M21A*+WALLCON+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 215676711 | 18.50 | 9.00 | 37600 | 1.98 | EPA 3970317 → |
EVD5X61M21A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 215676771 | 18.50 | 9.00 | 37400 | 2.00 | EPA 3970444 → |
EVD5X61M21A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 215676781 | 18.50 | 9.00 | 37000 | 2.00 | EPA 3970449 → |
EVD5X61M21A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 215676801 | 18.50 | 9.00 | 37400 | 2.00 | EPA 3970551 → |
EVD5X61M21A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 215676811 | 18.50 | 9.00 | 37400 | 1.98 | EPA 3970562 → |
EVD5X60M21A*+WALLCON+ furnace: *80CSU1002120A*Cold climate designationAHRI reference: 215676431 | 18.50 | 9.00 | 36800 | 2.00 | EPA 3970776 → |
EVD5X60M21A*+WALLCON+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 215676451 | 18.50 | 9.00 | 37200 | 2.00 | EPA 3970839 → |
EVD5X60M21A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 215676511 | 18.50 | 9.00 | 36800 | 2.00 | EPA 3970897 → |
EVD5X60M21A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 215676531 | 18.50 | 9.00 | 37200 | 1.98 | EPA 3970917 → |
EVD5X60M21A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 215676541 | 18.50 | 9.00 | 37400 | 1.98 | EPA 3970930 → |
EVD5X60M21A*+WALLCON+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 215676571 | 18.50 | 9.00 | 36200 | 2.02 | EPA 3970960 → |
EVD5X60M24A*+WALLCON+ furnace: *80CSU1002120A*Cold climate designationAHRI reference: 215676601 | 18.50 | 9.00 | 36600 | 2.00 | EPA 3971045 → |
EVD5X60M24A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 215676641 | 18.50 | 9.00 | 36600 | 2.00 | EPA 3971082 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.