N5H8T48*K*AAA*
2-STAGE 18 SEER HP · source records, page 16
407 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 407 / 407 |
| EER2 · BTU/Wh | 11.7–13.5 | 407 / 407 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 407 / 407 |
| Cooling capacity · BTU/h | 45,500–50,500 | 407 / 407 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 48,500–52,500 | 407 / 407 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 30,000–32,600 | 407 / 407 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,800–26,600 | 407 / 407 |
| COP at 5°F / −15°C | 2.06–2.32 | 407 / 407 |
| Equipment / loop type | HP - Split System | 407 / 407 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 407 / 407 |
| Compressor staging | Two-stage | 407 / 407 |
| Connected capability | No | 407 / 407 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X61M24A*+ furnace: *95CSU1002122B*AHRI reference: 215632988 | 16.00 | 8.10 | 26000 | 2.20 | EPA 3953513 → |
EA*5X61M24A*+ furnace: *95MSU1002122A*AHRI reference: 215633135 | 16.00 | 8.10 | 26200 | 2.20 | EPA 3953528 → |
EA*5X61M24A*+ furnace: *96CTN0802120B*AHRI reference: 215633149 | 16.00 | 8.10 | 26400 | 2.16 | EPA 3953546 → |
EA*5X61M24A*+ furnace: *96CTN1002122B*AHRI reference: 215633163 | 16.00 | 8.10 | 26600 | 2.16 | EPA 3953559 → |
EA*5X61M24A*+ furnace: *97CMN1002122B*AHRI reference: 215633030 | 16.00 | 8.10 | 26600 | 2.16 | EPA 3953601 → |
EA*5X61M24A*+ furnace: *96VSN1202422B*AHRI reference: 215633084 | 16.00 | 8.10 | 26200 | 2.20 | EPA 3953643 → |
EA*5X61M24A*+ furnace: *95MSU1002120A*AHRI reference: 215633119 | 16.00 | 8.10 | 26000 | 2.20 | EPA 3953658 → |
ESH5X48M12A*+ furnace: *80VTL0902120B*AHRI reference: 215633540 | 16.00 | 8.00 | 25000 | 2.20 | EPA 3953673 → |
ESH5X48M12A*+ furnace: *80VTL1102122B*AHRI reference: 215633556 | 16.00 | 8.00 | 25000 | 2.20 | EPA 3953693 → |
EA*5X61M24A*+ furnace: OLV154F20AAHRI reference: 215633258 | 16.00 | 8.10 | 26000 | 2.20 | EPA 3953742 → |
ESH5X48M12A*+ furnace: *80VSL0902120B*AHRI reference: 215633341 | 16.00 | 8.00 | 25000 | 2.20 | EPA 3953769 → |
ESH5X48M12A*+ furnace: *80VSL1102122B*AHRI reference: 215633354 | 16.00 | 8.00 | 25000 | 2.20 | EPA 3953784 → |
ESH5X48M12A*+ furnace: *80CTL1102120B*AHRI reference: 215633493 | 16.00 | 8.00 | 24800 | 2.20 | EPA 3953834 → |
ESH5X48M12A*+ furnace: *80CTL1352422B*AHRI reference: 215633507 | 16.00 | 8.00 | 24800 | 2.20 | EPA 3953848 → |
ESH5X48M12A*+ furnace: *96VTN1002120B*AHRI reference: 215633930 | 16.00 | 8.00 | 25200 | 2.20 | EPA 3953864 → |
ESH5X48M12A*+ furnace: *96VTN1002122B*AHRI reference: 215633945 | 16.00 | 8.00 | 24800 | 2.25 | EPA 3953880 → |
ESH5X60M12A*+ furnace: *80VSL0902120B*AHRI reference: 215634059 | 16.00 | 8.00 | 25000 | 2.25 | EPA 3953906 → |
ESH5X60M12A*+ furnace: *96CTN0802120B*AHRI reference: 215634545 | 16.00 | 8.00 | 25200 | 2.20 | EPA 3953943 → |
ESH5X60M12A*+ furnace: *96CTN1002122B*AHRI reference: 215634559 | 16.00 | 8.00 | 25200 | 2.25 | EPA 3953962 → |
ESH5X60M12A*+ furnace: *96CTN1202422B*AHRI reference: 215634573 | 16.00 | 8.00 | 25400 | 2.20 | EPA 3953974 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →