Keeprite / AIR-SOURCE HEAT PUMP

N5H8T48*K*AAA*

2-STAGE 18 SEER HP · source records, page 15

407 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18407 / 407
EER2 · BTU/Wh11.7–13.5407 / 407
HSPF2 · BTU/Wh7.8–8.5407 / 407
Cooling capacity · BTU/h45,500–50,500407 / 407
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500407 / 407
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600407 / 407
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600407 / 407
COP at 5°F / −15°C2.06–2.32407 / 407
Equipment / loop typeHP - Split System407 / 407
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)407 / 407
Compressor stagingTwo-stage407 / 407
Connected capabilityNo407 / 407

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X61M21A*+ furnace: *95CSU0802120B*AHRI reference: 21563255416.008.10260002.20EPA 3953141
EA*5X61M21A*+ furnace: *95CSU1002122B*AHRI reference: 21563256816.008.10256002.22EPA 3953151
EA*5X61M21A*+ furnace: *96VSN1002120B*AHRI reference: 21563263716.008.10258002.20EPA 3953171
EA*5X61M21A*+ furnace: *95MSU0802120A*AHRI reference: 21563267216.008.10256002.20EPA 3953188
EA*5X61M21A*+ furnace: *95MSU1002120A*AHRI reference: 21563269116.008.10256002.20EPA 3953207
EA*5X61M21A*+ furnace: *96CTN0802120B*AHRI reference: 21563272116.008.10258002.20EPA 3953236
EA*5X61M21A*+ furnace: *96CTN1002122B*AHRI reference: 21563273516.008.10260002.20EPA 3953249
EA*5X61M21A*+ furnace: *96VTN0802120B*AHRI reference: 21563275216.008.10256002.20EPA 3953270
EA*5X61M21A*+ furnace: *96VTN1002120B*AHRI reference: 21563277016.008.10256002.20EPA 3953286
EA*5X61M24A*+ furnace: *80VSL0902120B*AHRI reference: 21563279916.008.10260002.20EPA 3953299
EA*5X61M24A*+ furnace: *80VSL1102122B*AHRI reference: 21563281216.008.10260002.20EPA 3953313
EA*5X61M24A*+ furnace: *96VTN1002122B*AHRI reference: 21563322716.008.10258002.20EPA 3953352
EA*5X61M24A*+ furnace: *96VTN1202422B*AHRI reference: 21563324516.008.10266002.16EPA 3953369
EA*5X61M24A*+ furnace: *80VSL1352422B*AHRI reference: 21563282516.008.10260002.18EPA 3953379
EA*5X61M24A*+ furnace: *80MSU1002120A*AHRI reference: 21563286016.008.10262002.18EPA 3953414
EA*5X61M24A*+ furnace: *80CTL0902120B*AHRI reference: 21563289016.008.10258002.20EPA 3953430
EA*5X61M24A*+ furnace: *80CTL1102120B*AHRI reference: 21563290416.008.10264002.18EPA 3953445
EA*5X61M24A*+ furnace: *80CTL1352422B*AHRI reference: 21563291816.008.10262002.18EPA 3953457
EA*5X61M24A*+ furnace: *80VTL0902120B*AHRI reference: 21563293516.008.10260002.20EPA 3953478
EA*5X61M24A*+ furnace: *80VTL1102122B*AHRI reference: 21563295116.008.10258002.20EPA 3953492

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →