N5H8T48*K*AAA*
2-STAGE 18 SEER HP · source records, page 11
407 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 407 / 407 |
| EER2 · BTU/Wh | 11.7–13.5 | 407 / 407 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 407 / 407 |
| Cooling capacity · BTU/h | 45,500–50,500 | 407 / 407 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 48,500–52,500 | 407 / 407 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 30,000–32,600 | 407 / 407 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,800–26,600 | 407 / 407 |
| COP at 5°F / −15°C | 2.06–2.32 | 407 / 407 |
| Equipment / loop type | HP - Split System | 407 / 407 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 407 / 407 |
| Compressor staging | Two-stage | 407 / 407 |
| Connected capability | No | 407 / 407 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X61M21A*+ furnace: *80CTL0902120B*AHRI reference: 215632476 | 16.50 | 8.10 | 25400 | 2.22 | EPA 3952771 → |
EA*5X61M21A*+ furnace: *80CTL1102120B*AHRI reference: 215632490 | 16.50 | 8.10 | 25800 | 2.20 | EPA 3952785 → |
EA*5X61M21A*+ furnace: *97CMN1002122B*AHRI reference: 215632610 | 16.50 | 8.10 | 26000 | 2.20 | EPA 3952962 → |
EA*5X61M21A*+ furnace: *80VSL0902120B*AHRI reference: 215632351 | 16.50 | 8.10 | 25600 | 2.22 | EPA 3953021 → |
EA*5X61M21A*+ furnace: *80VSL1102122B*AHRI reference: 215632364 | 16.50 | 8.10 | 25400 | 2.22 | EPA 3953034 → |
EA*5X61M21A*+ furnace: *80MSU0601716A*AHRI reference: 215632380 | 16.50 | 8.10 | 25400 | 2.22 | EPA 3953050 → |
EA*5X61M21A*+ furnace: *80MSU0802120A*AHRI reference: 215632399 | 16.50 | 8.10 | 25200 | 2.22 | EPA 3953071 → |
EA*5X61M21A*+ furnace: *80VTL0902120B*AHRI reference: 215632523 | 16.50 | 8.10 | 25600 | 2.22 | EPA 3953109 → |
EA*5X61M21A*+ furnace: *95MSU1002122A*AHRI reference: 215632707 | 16.50 | 8.10 | 25600 | 2.22 | EPA 3953223 → |
EA*5X61M24A*+ furnace: *80MSU0802120A*AHRI reference: 215632841 | 16.50 | 8.10 | 25600 | 2.20 | EPA 3953396 → |
EVM5X60M21A*+ furnace: *97CTN0802120A*AHRI reference: 215722039 | 16.50 | 8.00 | 25200 | 2.10 | EPA 3981684 → |
EVM5X60M21A*+ furnace: *97VTN0802120A*AHRI reference: 215722070 | 16.50 | 8.00 | 24800 | 2.12 | EPA 3981712 → |
EVM5X60M21A*+ furnace: *97VTN1002120A*AHRI reference: 215722086 | 16.50 | 8.00 | 24600 | 2.14 | EPA 3981727 → |
EVD5X48M21A*+ furnace: *80CSU0802120B*AHRI reference: 215722114 | 16.50 | 8.00 | 24000 | 2.14 | EPA 3981748 → |
EVD5X48M21A*+ furnace: *97CTN1002122A*AHRI reference: 215722128 | 16.50 | 8.10 | 24400 | 2.15 | EPA 3981772 → |
EVD5X48M21A*+ furnace: *97VTN1002120A*AHRI reference: 215722145 | 16.50 | 8.00 | 24400 | 2.12 | EPA 3981786 → |
EVD5X49M24A*+ furnace: *97CTN1202422A*AHRI reference: 215722173 | 16.50 | 8.00 | 25200 | 2.10 | EPA 3981882 → |
EVD5X60M21A*+ furnace: *80CSU0401712B*AHRI reference: 215722200 | 16.50 | 8.00 | 24600 | 2.14 | EPA 3981907 → |
EVD5X60M21A*+ furnace: *80CSU1002120B*AHRI reference: 215722228 | 16.50 | 8.00 | 24600 | 2.14 | EPA 3981937 → |
EA*5X61M21A*+ furnace: *97VTN1002122A*AHRI reference: 215721841 | 16.50 | 8.00 | 25200 | 2.24 | EPA 3982254 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →