Keeprite / AIR-SOURCE HEAT PUMP

N5H8T48*K*AAA*

2-STAGE 18 SEER HP · source records, page 10

407 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18407 / 407
EER2 · BTU/Wh11.7–13.5407 / 407
HSPF2 · BTU/Wh7.8–8.5407 / 407
Cooling capacity · BTU/h45,500–50,500407 / 407
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500407 / 407
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600407 / 407
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600407 / 407
COP at 5°F / −15°C2.06–2.32407 / 407
Equipment / loop typeHP - Split System407 / 407
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)407 / 407
Compressor stagingTwo-stage407 / 407
Connected capabilityNo407 / 407

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X60M21A*+ furnace: *96VTN1002120B*AHRI reference: 21562499216.508.10246002.14EPA 3949132
EVD5X60M21A*+ furnace: *80CTL0702120B*AHRI reference: 21562479116.508.10256002.06EPA 3949199
EVD5X61M21A*+ furnace: *80CTL0702120B*AHRI reference: 21562510316.508.10256002.08EPA 3949313
EVD5X61M24A*+ furnace: *95MSU0802120A*AHRI reference: 21562563016.508.10252002.12EPA 3949407
EVD5X61M21A*+ furnace: *95MSU0802120A*AHRI reference: 21562526416.508.10252002.10EPA 3949563
EVD5X61M24A*+ furnace: *95CSU0802120B*AHRI reference: 21562553216.508.10256002.08EPA 3949652
EVD5X61M24A*+ furnace: *97CMN1202422B*AHRI reference: 21562557416.508.10252002.12EPA 3949680
EVD5X61M24A*+ furnace: *80CTL0702120B*AHRI reference: 21562544816.508.10256002.10EPA 3949783
EVD5X61M24A*+ furnace: *96CTN0802120B*AHRI reference: 21562567916.508.10256002.10EPA 3950008
EVD5X61M24A*+ furnace: *96VTN1202422B*AHRI reference: 21562577516.508.10252002.12EPA 3950167
EVD5X48M21A*+ furnace: *80VSL1102122B*AHRI reference: 21562884816.508.10242002.14EPA 3950390
EVD5X61M21A*+TDRAHRI reference: 21562870516.508.10242002.16EPA 3950476
EVD5X61M24A*+TDRAHRI reference: 21562872416.508.10242002.16EPA 3950496
EA*5X61M21A*+ furnace: *96VTN1002122B*AHRI reference: 21562883516.508.10252002.24EPA 3950514
EVD5X60M21A*+TDRAHRI reference: 21562866716.508.00240002.15EPA 3950641
EVM5X49M21A*+TDRAHRI reference: 21562853416.508.00240002.15EPA 3950773
EVM5X60M21A*+TDRAHRI reference: 21562855316.508.00240002.15EPA 3950792
EVM5X61M24A*+TDRAHRI reference: 21562859116.508.10242002.16EPA 3950833
EA*5X60M24A*+ furnace: *80MSU0802120A*AHRI reference: 21563186516.508.10256002.20EPA 3952583
EA*5X61M21A*+ furnace: *80MSU1002120A*AHRI reference: 21563241816.508.10258002.22EPA 3952728

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →