N5H8T48*K*AAA*
2-STAGE 18 SEER HP · source records, page 10
407 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 407 / 407 |
| EER2 · BTU/Wh | 11.7–13.5 | 407 / 407 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 407 / 407 |
| Cooling capacity · BTU/h | 45,500–50,500 | 407 / 407 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 48,500–52,500 | 407 / 407 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 30,000–32,600 | 407 / 407 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,800–26,600 | 407 / 407 |
| COP at 5°F / −15°C | 2.06–2.32 | 407 / 407 |
| Equipment / loop type | HP - Split System | 407 / 407 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 407 / 407 |
| Compressor staging | Two-stage | 407 / 407 |
| Connected capability | No | 407 / 407 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X60M21A*+ furnace: *96VTN1002120B*AHRI reference: 215624992 | 16.50 | 8.10 | 24600 | 2.14 | EPA 3949132 → |
EVD5X60M21A*+ furnace: *80CTL0702120B*AHRI reference: 215624791 | 16.50 | 8.10 | 25600 | 2.06 | EPA 3949199 → |
EVD5X61M21A*+ furnace: *80CTL0702120B*AHRI reference: 215625103 | 16.50 | 8.10 | 25600 | 2.08 | EPA 3949313 → |
EVD5X61M24A*+ furnace: *95MSU0802120A*AHRI reference: 215625630 | 16.50 | 8.10 | 25200 | 2.12 | EPA 3949407 → |
EVD5X61M21A*+ furnace: *95MSU0802120A*AHRI reference: 215625264 | 16.50 | 8.10 | 25200 | 2.10 | EPA 3949563 → |
EVD5X61M24A*+ furnace: *95CSU0802120B*AHRI reference: 215625532 | 16.50 | 8.10 | 25600 | 2.08 | EPA 3949652 → |
EVD5X61M24A*+ furnace: *97CMN1202422B*AHRI reference: 215625574 | 16.50 | 8.10 | 25200 | 2.12 | EPA 3949680 → |
EVD5X61M24A*+ furnace: *80CTL0702120B*AHRI reference: 215625448 | 16.50 | 8.10 | 25600 | 2.10 | EPA 3949783 → |
EVD5X61M24A*+ furnace: *96CTN0802120B*AHRI reference: 215625679 | 16.50 | 8.10 | 25600 | 2.10 | EPA 3950008 → |
EVD5X61M24A*+ furnace: *96VTN1202422B*AHRI reference: 215625775 | 16.50 | 8.10 | 25200 | 2.12 | EPA 3950167 → |
EVD5X48M21A*+ furnace: *80VSL1102122B*AHRI reference: 215628848 | 16.50 | 8.10 | 24200 | 2.14 | EPA 3950390 → |
EVD5X61M21A*+TDRAHRI reference: 215628705 | 16.50 | 8.10 | 24200 | 2.16 | EPA 3950476 → |
EVD5X61M24A*+TDRAHRI reference: 215628724 | 16.50 | 8.10 | 24200 | 2.16 | EPA 3950496 → |
EA*5X61M21A*+ furnace: *96VTN1002122B*AHRI reference: 215628835 | 16.50 | 8.10 | 25200 | 2.24 | EPA 3950514 → |
EVD5X60M21A*+TDRAHRI reference: 215628667 | 16.50 | 8.00 | 24000 | 2.15 | EPA 3950641 → |
EVM5X49M21A*+TDRAHRI reference: 215628534 | 16.50 | 8.00 | 24000 | 2.15 | EPA 3950773 → |
EVM5X60M21A*+TDRAHRI reference: 215628553 | 16.50 | 8.00 | 24000 | 2.15 | EPA 3950792 → |
EVM5X61M24A*+TDRAHRI reference: 215628591 | 16.50 | 8.10 | 24200 | 2.16 | EPA 3950833 → |
EA*5X60M24A*+ furnace: *80MSU0802120A*AHRI reference: 215631865 | 16.50 | 8.10 | 25600 | 2.20 | EPA 3952583 → |
EA*5X61M21A*+ furnace: *80MSU1002120A*AHRI reference: 215632418 | 16.50 | 8.10 | 25800 | 2.22 | EPA 3952728 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →