XH660E2S11
LX SERIES · source records, page 6
121 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH660E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 121 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 121 / 121 |
| EER2 · BTU/Wh | 11–12 | 121 / 121 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 121 / 121 |
| Cooling capacity · BTU/h | 52,500–55,000 | 121 / 121 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 56,000–60,000 | 121 / 121 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 37,800–39,500 | 121 / 121 |
| Heating capacity at 5°F / −15°C · BTU/h | 30,000–32,600 | 121 / 121 |
| COP at 5°F / −15°C | 2–2.38 | 121 / 121 |
| Equipment / loop type | HP - Split System | 121 / 121 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 121 / 121 |
| Compressor staging | Two-stage | 121 / 121 |
| Connected capability | No | 121 / 121 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF60C5CHS1+JMET16CS2N1AHRI reference: 217017887 | 15.20 | 8.10 | 31400 | 2.28 | EPA 4571898 → |
CTF60C5CHS1+ furnace: Z9ET100C16SMPS1AHRI reference: 217017882 | 15.20 | 8.00 | 31800 | 2.24 | EPA 4571900 → |
CTF60C5CHS1+ furnace: Z8ES120C16LMPS1AHRI reference: 217017877 | 15.20 | 8.10 | 31400 | 2.26 | EPA 4571905 → |
CTF60C5CHS1+ furnace: Z8ES120C16SMPS1AHRI reference: 217017876 | 15.20 | 8.10 | 31400 | 2.26 | EPA 4571906 → |
CTF60C5CHS1+ furnace: Z8ES100C20LMPS1AHRI reference: 217017870 | 15.20 | 8.10 | 31200 | 2.28 | EPA 4571908 → |
CTF60C5CHS1+ furnace: Z8ES100C20SMPS1AHRI reference: 217017869 | 15.20 | 8.10 | 31200 | 2.28 | EPA 4571909 → |
CTF60D5CHS1+JMVT20DC2N1AHRI reference: 217017865 | 15.20 | 8.10 | 31000 | 2.30 | EPA 4571913 → |
CTF60C5CHS1+ furnace: Z9ES100C16SMPS1AHRI reference: 217017856 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4571921 → |
CTU60D5XHS1+JMET18DS2N1+TXVAHRI reference: 217017854 | 15.20 | 8.10 | 31200 | 2.30 | EPA 4571923 → |
CTU60D5XHS1+JMC20D2SN1+TXVAHRI reference: 217017849 | 15.20 | 8.10 | 31000 | 2.30 | EPA 4571927 → |
CTF60C5CHS1+JMVT16CC2N1AHRI reference: 217017840 | 15.20 | 8.10 | 31200 | 2.28 | EPA 4571933 → |
CTF60D5CHS1+JME18D2SN1AHRI reference: 217017830 | 15.20 | 8.10 | 31200 | 2.30 | EPA 4571941 → |
CTF60C5CHS1+ furnace: Z9ET100C20SMPS1AHRI reference: 217017829 | 15.20 | 8.10 | 31800 | 2.24 | EPA 4571942 → |
CTF60D5CJS1+ furnace: Z9ES120D20SMPS1AHRI reference: 217017826 | 15.20 | 8.10 | 32400 | 2.32 | EPA 4571944 → |
CTF60C5CHS1+JMVT17CC2N1AHRI reference: 217017812 | 15.20 | 8.10 | 31200 | 2.28 | EPA 4571954 → |
CTF60C5CHS1+JMC16C2SN1AHRI reference: 217017804 | 15.20 | 8.10 | 31200 | 2.28 | EPA 4571961 → |
CTF60C5CHS1+ furnace: Z9ES100C20SMPS1AHRI reference: 217017798 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4571966 → |
CTF60D5CHS1+JMC20D2SN1AHRI reference: 217017795 | 15.20 | 8.10 | 31000 | 2.30 | EPA 4571969 → |
CTF60D5CHS1+ furnace: Z9ES120D20SMPS1AHRI reference: 217017789 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4571972 → |
CTF60C5CHS1+JME16C2SN1AHRI reference: 217017767 | 15.20 | 8.10 | 31200 | 2.30 | EPA 4571989 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →