Johnson Controls / AIR-SOURCE HEAT PUMP

XH660E2S11

LX SERIES · source records, page 2

121 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity52,500–55,000BTU/h

Each efficiency range summarizes published EPA records for XH660E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 121 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16121 / 121
EER2 · BTU/Wh11–12121 / 121
HSPF2 · BTU/Wh7.8–8.5121 / 121
Cooling capacity · BTU/h52,500–55,000121 / 121
Heating capacity at 47°F / 8.3°C · BTU/h56,000–60,000121 / 121
Heating capacity at 17°F / −8.3°C · BTU/h37,800–39,500121 / 121
Heating capacity at 5°F / −15°C · BTU/h30,000–32,600121 / 121
COP at 5°F / −15°C2–2.38121 / 121
Equipment / loop typeHP - Split System121 / 121
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)121 / 121
Compressor stagingTwo-stage121 / 121
Connected capabilityNo121 / 121

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF60C5CHS1+ furnace: Z8VT100C16SMPC1AHRI reference: 21744520615.208.10318002.26EPA 4045208 →
CTF60C5CHS1+ furnace: Z8VT120C20SMPC1AHRI reference: 21744520715.208.10318002.26EPA 4045209 →
CTF60C5CHS1+ furnace: Z8VT100C20SMPC1AHRI reference: 21744520815.208.10316002.26EPA 4045210 →
CTM60C5CHS1+ furnace: Z8VT120C20SMPC1AHRI reference: 21744520915.208.10324002.24EPA 4045211 →
CTM60C5CHS1+ furnace: Z8VT100C20SMPC1AHRI reference: 21744521015.208.10316002.26EPA 4045212 →
CTF60C5CHS1+ furnace: Z8VT080C16SMPC1AHRI reference: 21744521115.208.10316002.26EPA 4045213 →
CTM60C5CHS1+ furnace: Z8VT100C16SMPC1AHRI reference: 21744521215.208.10314002.26EPA 4045214 →
CTM60D5CJS1+ furnace: TP9C120D20MP13AHRI reference: 21799440315.208.00314002.00EPA 4570865 →
CTM60D5CJS1+ furnace: TM9V120D20MP12AHRI reference: 21799439815.208.00314002.00EPA 4570870 →
CTF60D5CJS1+ furnace: TP9C120D20MP13AHRI reference: 21799439115.208.00312002.00EPA 4570877 →
CTF60D5CJS1+ furnace: TM9V120D20MP12AHRI reference: 21799438615.208.00312002.00EPA 4570882 →
CTM60D5CHS1+ furnace: TP9C120D20MP13AHRI reference: 21799435515.208.00304002.00EPA 4570889 →
CTM60D5CHS1+ furnace: TM9V120D20MP12AHRI reference: 21799435015.208.00304002.00EPA 4570894 →
CTU60D5XHS1+TXV+ furnace: TP9C120D20MP13AHRI reference: 21799434315.208.00304002.00EPA 4570901 →
CTU60D5XHS1+TXV+ furnace: TM9V120D20MP12AHRI reference: 21799433815.208.00304002.00EPA 4570906 →
CTF60D5CHS1+ furnace: TP9C120D20MP13AHRI reference: 21799433115.208.00304002.00EPA 4570913 →
CTF60D5CHS1+ furnace: TM9V120D20MP12AHRI reference: 21799432615.208.00304002.00EPA 4570918 →
CTM60C5CHS1+ furnace: TP9C100C16MP13AHRI reference: 21799431915.208.00308002.00EPA 4570925 →
CTM60C5CHS1+ furnace: TM9V100C16MP12AHRI reference: 21799431415.208.00308002.00EPA 4570930 →
CTM60C5CHS1+ furnace: TP9C100C20MP13AHRI reference: 21799430715.208.00308002.00EPA 4570937 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →