XH648E2S11
LX SERIES · source records, page 3
279 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH648E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 279 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 279 / 279 |
| EER2 · BTU/Wh | 11.7–12 | 279 / 279 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 279 / 279 |
| Cooling capacity · BTU/h | 45,000–49,000 | 279 / 279 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,000–50,000 | 279 / 279 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 31,800–34,000 | 279 / 279 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,000–27,800 | 279 / 279 |
| COP at 5°F / −15°C | 2–2.4 | 279 / 279 |
| Equipment / loop type | HP - Split System | 279 / 279 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 279 / 279 |
| Compressor staging | Two-stage | 279 / 279 |
| Connected capability | No | 279 / 279 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTU60D5XHS1+TXV+ furnace: Z8ES130D20LMPS1AHRI reference: 217020805 | 16.00 | 8.10 | 27000 | 2.36 | EPA 4014515 → |
CTF60D5CHS1+ furnace: Z8ES130D20LMPS1AHRI reference: 217020806 | 16.00 | 8.10 | 27000 | 2.36 | EPA 4014516 → |
CTM60D5CHS1+ furnace: Z8ES130D20LMPS1AHRI reference: 217020808 | 16.00 | 8.10 | 27000 | 2.36 | EPA 4014517 → |
CTU60D5XGS1+TXV+ furnace: Z8ES130D20LMPS1AHRI reference: 217020809 | 16.00 | 8.10 | 27400 | 2.28 | EPA 4014518 → |
CTF60D5CGS1+ furnace: Z8ES130D20LMPS1AHRI reference: 217020810 | 16.00 | 8.10 | 27400 | 2.28 | EPA 4014519 → |
CTU60D5XHS1+TXV+ furnace: Z9ES120D20SMPS1AHRI reference: 217020815 | 16.00 | 8.10 | 27200 | 2.32 | EPA 4014520 → |
CTF60D5CHS1+ furnace: Z9ES120D20SMPS1AHRI reference: 217020816 | 16.00 | 8.10 | 27200 | 2.32 | EPA 4014521 → |
CTM60D5CHS1+ furnace: Z9ES120D20SMPS1AHRI reference: 217020817 | 16.00 | 8.10 | 27600 | 2.30 | EPA 4014522 → |
CTM60C5CHS1+ furnace: Z9ES100C20SMPS1AHRI reference: 217020818 | 16.00 | 8.10 | 27800 | 2.28 | EPA 4014523 → |
CTF60C5CGS1+ furnace: Z9ES100C20SMPS1AHRI reference: 217020820 | 16.00 | 8.10 | 27400 | 2.22 | EPA 4014524 → |
CTU60C5XGS1+TXV+ furnace: Z9ES100C20SMPS1AHRI reference: 217020821 | 16.00 | 8.10 | 27400 | 2.22 | EPA 4014525 → |
CTF60C5CHS1+ furnace: Z9ES100C20SMPS1AHRI reference: 217020823 | 16.00 | 8.10 | 27400 | 2.30 | EPA 4014526 → |
CTU60C5XGS1+JMET12CS2N1+TXVAHRI reference: 217020658 | 16.00 | 8.10 | 26800 | 2.26 | EPA 4014651 → |
CTM60C5CHS1+JMVT16CC2N1AHRI reference: 217020597 | 16.00 | 8.10 | 27000 | 2.36 | EPA 4014694 → |
CTF60C5CHS1+JMET16CS2N1AHRI reference: 217020599 | 16.00 | 8.10 | 27000 | 2.34 | EPA 4014695 → |
CTF60D5CHS1+JMVT20DC2N1AHRI reference: 217020600 | 16.00 | 8.10 | 27000 | 2.38 | EPA 4014696 → |
CTU60D5XHS1+JMVT20DC2N1+TXVAHRI reference: 217020601 | 16.00 | 8.10 | 27000 | 2.38 | EPA 4014697 → |
CTU60D5XGS1+JMVT20DC2N1+TXVAHRI reference: 217020598 | 16.00 | 8.10 | 27200 | 2.30 | EPA 4014698 → |
JHE60C5CH2SS1AHRI reference: 217020602 | 16.00 | 8.10 | 27200 | 2.34 | EPA 4014699 → |
CTF60C5CHS1+JMC17C2SN1AHRI reference: 217020603 | 16.00 | 8.10 | 27000 | 2.36 | EPA 4014700 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →