XH636E2S11
LX SERIES · source records, page 5
236 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH636E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 236 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 236 / 236 |
| EER2 · BTU/Wh | 11–12 | 236 / 236 |
| HSPF2 · BTU/Wh | 8–8.5 | 236 / 236 |
| Cooling capacity · BTU/h | 32,800–36,000 | 236 / 236 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,000–36,200 | 236 / 236 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 22,000–23,800 | 236 / 236 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,600–19,800 | 236 / 236 |
| COP at 5°F / −15°C | 2–2.5 | 236 / 236 |
| Equipment / loop type | HP - Split System | 236 / 236 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 236 / 236 |
| Compressor staging | Two-stage | 236 / 236 |
| Connected capability | No | 236 / 236 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF36C5CDS1+JMVT17CC2N1AHRI reference: 217017576 | 16.00 | 8.50 | 18800 | 2.38 | EPA 4012992 → |
CTF36C5CDS1+JMC16C2SN1AHRI reference: 217017577 | 16.00 | 8.50 | 18800 | 2.40 | EPA 4012993 → |
CTF36C5CDS1+JME16C2SN1AHRI reference: 217017583 | 16.00 | 8.10 | 18500 | 2.40 | EPA 4012998 → |
CTU36B5XDS1+JMC12B2SN1+TXVAHRI reference: 217017584 | 16.00 | 8.10 | 18700 | 2.34 | EPA 4012999 → |
CTF36B5CDS1+JMC12B2SN1AHRI reference: 217017585 | 16.00 | 8.10 | 18700 | 2.34 | EPA 4013000 → |
CTF36C5CDS1+JMVT16CC2N1AHRI reference: 217017586 | 16.00 | 8.50 | 18800 | 2.40 | EPA 4013001 → |
CTU36B5XDS1+JMET12BS2N1+TXVAHRI reference: 217017592 | 16.00 | 8.10 | 18600 | 2.36 | EPA 4013004 → |
CTF36B5CDS1+JMET12BS2N1AHRI reference: 217017593 | 16.00 | 8.10 | 18600 | 2.36 | EPA 4013005 → |
CTU36B5XDS1+JMVT12BC2N1+TXVAHRI reference: 217017594 | 16.00 | 8.10 | 18700 | 2.34 | EPA 4013006 → |
CTF36B5CDS1+JMVT12BC2N1AHRI reference: 217017595 | 16.00 | 8.10 | 18700 | 2.34 | EPA 4013007 → |
CTF36C5CDS1+JMET12CS2N1AHRI reference: 217017596 | 16.00 | 8.10 | 18800 | 2.36 | EPA 4013008 → |
CTM36C5CDS1+ furnace: Z9ES080C20SMPS1AHRI reference: 217018411 | 16.00 | 8.10 | 18900 | 2.32 | EPA 4013512 → |
CTM36C5CDS1+ furnace: Z8ES120C20LMPS1AHRI reference: 217018412 | 16.00 | 8.10 | 18800 | 2.32 | EPA 4013513 → |
CTM36C5CDS1+ furnace: Z8ES120C16LMPS1AHRI reference: 217018413 | 16.00 | 8.10 | 18500 | 2.36 | EPA 4013514 → |
CTM48C5CFS1+ furnace: Z8ES120C16LMPS1AHRI reference: 217018414 | 16.00 | 8.50 | 19000 | 2.46 | EPA 4013515 → |
CTM36C5CDS1+ furnace: Z8ES100C16LMPS1AHRI reference: 217018418 | 16.00 | 8.10 | 18600 | 2.34 | EPA 4013516 → |
CTM48C5CFS1+ furnace: Z8ES100C16LMPS1AHRI reference: 217018417 | 16.00 | 8.50 | 19500 | 2.42 | EPA 4013517 → |
CTM48C5CFS1+ furnace: Z8ES080C20LMPS1AHRI reference: 217018420 | 16.00 | 8.50 | 19300 | 2.44 | EPA 4013518 → |
CTM36C5CDS1+ furnace: Z8ES080C20LMPS1AHRI reference: 217018421 | 16.00 | 8.10 | 18700 | 2.34 | EPA 4013519 → |
CTM36C5CDS1+ furnace: Z8ET100C20LMPS1AHRI reference: 217018423 | 16.00 | 8.10 | 18300 | 2.34 | EPA 4013520 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.