Johnson Controls / AIR-SOURCE HEAT PUMP

XH636E2S11

LX SERIES · source records, page 10

236 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity32,800–36,000BTU/h

Each efficiency range summarizes published EPA records for XH636E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 236 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17236 / 236
EER2 · BTU/Wh11–12236 / 236
HSPF2 · BTU/Wh8–8.5236 / 236
Cooling capacity · BTU/h32,800–36,000236 / 236
Heating capacity at 47°F / 8.3°C · BTU/h34,000–36,200236 / 236
Heating capacity at 17°F / −8.3°C · BTU/h22,000–23,800236 / 236
Heating capacity at 5°F / −15°C · BTU/h17,600–19,800236 / 236
COP at 5°F / −15°C2–2.5236 / 236
Equipment / loop typeHP - Split System236 / 236
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)236 / 236
Compressor stagingTwo-stage236 / 236
Connected capabilityNo236 / 236

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF48C5CFS1+ furnace: TP9C080C16MP13AHRI reference: 21799404216.008.10182002.00EPA 4514692 →
CTU48C5XFS1+TXV+ furnace: TM9V080C16MP12AHRI reference: 21799404916.008.10182002.00EPA 4514697 →
CTU48C5XFS1+TXV+ furnace: TP9C080C16MP13AHRI reference: 21799405416.008.10182002.00EPA 4514703 →
CTF48C5CFS1+ furnace: TM9V100C16MP12AHRI reference: 21799395316.008.10186002.00EPA 4514964 →
CTF48C5CFS1+ furnace: TP9C100C16MP13AHRI reference: 21799395816.008.10186002.00EPA 4514968 →
CTU48C5XFS1+TXV+ furnace: TM9V100C16MP12AHRI reference: 21799396516.008.10186002.00EPA 4514976 →
CTU36B5XDS1+TXV+ furnace: Z9ES080B12SMPS1AHRI reference: 21701750115.208.10186002.30EPA 4012916 →
CTF36B5CDS1+ furnace: Z9ES080B12SMPS1AHRI reference: 21701750215.208.10186002.30EPA 4012917 →
CTU36B5XDS1+TXV+ furnace: Z9ET080B12SMPS1AHRI reference: 21701755715.208.10187002.30EPA 4012977 →
CTF36B5CDS1+ furnace: Z9ET080B12SMPS1AHRI reference: 21701755815.208.10187002.30EPA 4012978 →
CTM36B5CDS1+ furnace: Z8VT080B12SMPC1AHRI reference: 21744517915.208.10186002.32EPA 4045295 →
CTM36B5CDS1+ furnace: TM9V080B12MP12AHRI reference: 21799367815.208.10180002.00EPA 4514724 →
CTM36B5CDS1+ furnace: TP9C080B12MP13AHRI reference: 21799369015.208.10180002.00EPA 4514736 →
CTM36B5CDS1+ furnace: TM9V060B12MP12AHRI reference: 21799370615.208.10180002.00EPA 4514753 →
CTM36B5CDS1+ furnace: TP9C060B12MP13AHRI reference: 21799371815.208.10180002.00EPA 4514785 →
CTM36C5CDS1+ furnace: TM9V080C16MP12AHRI reference: 21799373515.208.10180002.00EPA 4514802 →
CTM36C5CDS1+ furnace: TP9C080C16MP13AHRI reference: 21799374715.208.10180002.00EPA 4514815 →
CTF36B5CDS1+ furnace: TM9V080B12MP12AHRI reference: 21799376615.208.10180002.00EPA 4514825 →
CTF36B5CDS1+ furnace: TP9C080B12MP13AHRI reference: 21799377515.208.10180002.00EPA 4514874 →
CTU36B5XDS1+TXV+ furnace: TM9V080B12MP12AHRI reference: 21799379315.208.10180002.00EPA 4514886 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →