Johnson Controls / AIR-SOURCE HEAT PUMP

XH636E2S11

LX SERIES

236 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity32,800–36,000BTU/h

Each efficiency range summarizes published EPA records for XH636E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 236 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17236 / 236
EER2 · BTU/Wh11–12236 / 236
HSPF2 · BTU/Wh8–8.5236 / 236
Cooling capacity · BTU/h32,800–36,000236 / 236
Heating capacity at 47°F / 8.3°C · BTU/h34,000–36,200236 / 236
Heating capacity at 17°F / −8.3°C · BTU/h22,000–23,800236 / 236
Heating capacity at 5°F / −15°C · BTU/h17,600–19,800236 / 236
COP at 5°F / −15°C2–2.5236 / 236
Equipment / loop typeHP - Split System236 / 236
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)236 / 236
Compressor stagingTwo-stage236 / 236
Connected capabilityNo236 / 236

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU48C5XFS1+TXV+ furnace: Z9ES080C16SMPS1AHRI reference: 21701749617.008.10189002.40EPA 4012911 →
CTF48C5CFS1+ furnace: Z9ES080C16SMPS1AHRI reference: 21701749717.008.10189002.40EPA 4012912 →
CTU48C5XFS1+TXV+ furnace: Z9ES080C20SMPS1AHRI reference: 21701749917.008.10194002.40EPA 4012914 →
CTF48C5CFS1+ furnace: Z9ES080C20SMPS1AHRI reference: 21701750017.008.10194002.40EPA 4012915 →
CTU48C5XFS1+TXV+ furnace: Z8ES100C16LMPS1AHRI reference: 21701751017.008.50195002.42EPA 4012919 →
CTU48C5XFS1+TXV+ furnace: Z8ES120C16LMPS1AHRI reference: 21701750717.008.50191002.44EPA 4012921 →
CTF48C5CFS1+ furnace: Z8ES120C16LMPS1AHRI reference: 21701750817.008.50191002.44EPA 4012922 →
CTF48C5CFS1+ furnace: Z8ES100C16LMPS1AHRI reference: 21701751117.008.50195002.42EPA 4012924 →
CTU48C5XFS1+TXV+ furnace: Z8ES080C20LMPS1AHRI reference: 21701751617.008.50193002.42EPA 4012929 →
CTF48C5CFS1+ furnace: Z8ES080C20LMPS1AHRI reference: 21701751717.008.50193002.42EPA 4012930 →
CTU48C5XFS1+TXV+ furnace: Z8ET100C20LMPS1AHRI reference: 21701751917.008.10192002.44EPA 4012932 →
CTF48C5CFS1+ furnace: Z8ET100C20LMPS1AHRI reference: 21701752017.008.10192002.44EPA 4012933 →
CTU48C5XFS1+TXV+ furnace: Z8ET120C20LMPS1AHRI reference: 21701752317.008.10194002.44EPA 4012936 →
CTF48C5CFS1+ furnace: Z8ET120C20LMPS1AHRI reference: 21701752417.008.10194002.44EPA 4012937 →
CTU48C5XFS1+TXV+ furnace: Z8ET100C16LMPS1AHRI reference: 21701752617.008.50193002.44EPA 4012939 →
CTF48C5CFS1+ furnace: Z8ET100C16LMPS1AHRI reference: 21701752817.008.50193002.44EPA 4012940 →
CTU48C5XFS1+TXV+ furnace: Z8ET080C16LMPS1AHRI reference: 21701753017.008.50193002.44EPA 4012943 →
CTF48C5CFS1+ furnace: Z8ET080C16LMPS1AHRI reference: 21701753117.008.50193002.44EPA 4012944 →
CTU48C5XFS1+TXV+ furnace: Z8ES120C16SMPS1AHRI reference: 21701753617.008.50191002.44EPA 4012949 →
CTF48C5CFS1+ furnace: Z8ES120C16SMPS1AHRI reference: 21701753717.008.50191002.44EPA 4012958 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.