Johnson Controls / AIR-SOURCE HEAT PUMP

XH624E2S11

LX SERIES · source records, page 3

80 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity22,800–24,200BTU/h

Each efficiency range summarizes published EPA records for XH624E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 80 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1680 / 80
EER2 · BTU/Wh11.7–1280 / 80
HSPF2 · BTU/Wh7.8–8.180 / 80
Cooling capacity · BTU/h22,800–24,20080 / 80
Heating capacity at 47°F / 8.3°C · BTU/h22,600–24,00080 / 80
Heating capacity at 17°F / −8.3°C · BTU/h14,500–15,50080 / 80
Heating capacity at 5°F / −15°C · BTU/h11,900–12,80080 / 80
COP at 5°F / −15°C2–2.380 / 80
Equipment / loop typeHP - Split System80 / 80
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)80 / 80
Compressor stagingTwo-stage80 / 80
Connected capabilityNo80 / 80

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF30C5ACS1+JME12C2SN1AHRI reference: 21701704316.007.80122002.16EPA 4572043 →
CTF30C5ACS1+JME16C2SN1AHRI reference: 21701703916.007.80122002.16EPA 4572047 →
CTU30B5XCS1+JME12B2SN1+TXVAHRI reference: 21701696316.007.80122002.14EPA 4572064 →
CTF30C5ACS1+ furnace: Z8ET120C20LMPS1AHRI reference: 21701691216.007.80123002.14EPA 4572082 →
CTF30C5ACS1+ furnace: Z9ET100C16SMPS1AHRI reference: 21701689616.007.80124002.10EPA 4572085 →
CTF30C5ACS1+JMET12CS2N1AHRI reference: 21701687216.007.80123002.14EPA 4572094 →
CTF30C5ACS1+JMET16CS2N1AHRI reference: 21701685716.007.80123002.16EPA 4572096 →
CTF30B5ACS1+JME12B2SN1AHRI reference: 21701683316.007.80122002.14EPA 4572102 →
CTU30B5XCS1+JMC12B2SN1+TXVAHRI reference: 21701680616.007.80122002.14EPA 4572109 →
CTF30B5ACS1+JMC12B2SN1AHRI reference: 21701680516.007.80122002.14EPA 4572110 →
CTU30B5XCS1+JMVT12BC2N1+TXVAHRI reference: 21701680416.007.80122002.14EPA 4572111 →
CTF30B5ACS1+JMVT12BC2N1AHRI reference: 21701680316.007.80122002.14EPA 4572112 →
CTF30A5ADS1+ furnace: Z8VT060A12SMPC1AHRI reference: 21744517115.208.10125002.26EPA 4045252 →
CTM36B5ADS1+ furnace: Z8VT080B12SMPC1AHRI reference: 21744517415.208.10124002.28EPA 4045269 →
CTF36C5ADS1+ furnace: TP9C100C16MP13AHRI reference: 21799360015.208.00120002.00EPA 4571097 →
CTM36C5ADS1+ furnace: TP9C100C16MP13AHRI reference: 21799359815.208.00120002.00EPA 4571099 →
CTM36B5ADS1+ furnace: TP9C080B12MP13AHRI reference: 21799359615.208.00120002.00EPA 4571101 →
CTU36B5XDS1+TXV+ furnace: TP9C080B12MP13AHRI reference: 21799359415.208.00120002.00EPA 4571103 →
CTF36B5ADS1+ furnace: TP9C080B12MP13AHRI reference: 21799359215.208.00120002.00EPA 4571105 →
CTF36C5ADS1+ furnace: TM9V100C16MP12AHRI reference: 21799358315.208.00120002.00EPA 4571108 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →