Johnson Controls / AIR-SOURCE HEAT PUMP

XH548E2S11

LX SERIES · source records, page 7

192 published source records · source checked Sep 21, 2026

SEER2 range15.2BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity44,500–48,000BTU/h

Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 192 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2192 / 192
EER2 · BTU/Wh11–12192 / 192
HSPF2 · BTU/Wh7.8–8.1192 / 192
Cooling capacity · BTU/h44,500–48,000192 / 192
Heating capacity at 47°F / 8.3°C · BTU/h45,000–48,000192 / 192
Heating capacity at 17°F / −8.3°C · BTU/h29,200–32,200192 / 192
Heating capacity at 5°F / −15°C · BTU/h24,600–27,000192 / 192
COP at 5°F / −15°C2.1–2.42192 / 192
Equipment / loop typeHP - Split System192 / 192
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)192 / 192
Compressor stagingTwo-stage192 / 192
Connected capabilityNo192 / 192

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM60D5CHS1+ furnace: Z8ES130D20LMPS1AHRI reference: 21678295015.208.10264002.40EPA 4046911
CTM60C5CHS1+ furnace: Z8ES080C20LMPS1AHRI reference: 21678361215.208.10262002.40EPA 4047044
CTF60C5CHS1+ furnace: Z8ES120C16LMPS1AHRI reference: 21678234015.208.10264002.36EPA 4047067
CTM60C5CHS1+ furnace: Z8ES120C16LMPS1AHRI reference: 21678292115.208.10264002.38EPA 4047071
CTF60C5CHS1+ furnace: Z8ES100C20LMPS1AHRI reference: 21678502915.208.10262002.38EPA 4047087
CTF60D5CHS1+ furnace: Z8ES130D20LMPS1AHRI reference: 21678504415.208.10266002.38EPA 4047092
CTM60C5CHS1+ furnace: Z8ES100C20LMPS1AHRI reference: 21678603215.208.10262002.40EPA 4047097
CTM60C5CHS1+ furnace: Z8ES120C20LMPS1AHRI reference: 21678651015.208.10262002.38EPA 4047102
CTU60D5XHS1+TXV+ furnace: Z8ES130D20LMPS1AHRI reference: 21678506015.208.10266002.38EPA 4047118
CTM60C5CGS1+ furnace: Z8ES100C20SMPS1AHRI reference: 21460545815.207.80256002.28EPA 4570762
CTM60C5CGS1+ furnace: Z8ES120C20SMPS1AHRI reference: 21460545315.207.80258002.26EPA 4570766
CTM60C5CGS1+JMC16C2SN1AHRI reference: 21442910715.207.80256002.28EPA 4570785
CTF60C5CGS1+JMET16CS2N1AHRI reference: 21442890215.207.80252002.24EPA 4570790
CTM60D5CGS1+JMET18DS2N1AHRI reference: 21442735215.207.80254002.28EPA 4570805
CTM60C5CGS1+ furnace: Z8ES100C16LMPS1AHRI reference: 21678630115.207.80260002.26EPA 4572124
CTF60C5CHS1+ furnace: Z8ES080C16LMPS1AHRI reference: 21678606215.207.80262002.36EPA 4572129
CTF60C5CHS1+ furnace: Z8ES100C16LMPS1AHRI reference: 21678604715.207.80260002.38EPA 4572134
CTU60C5XGS1+TXV+ furnace: Z8ES120C16LMPS1AHRI reference: 21678585815.207.80258002.20EPA 4572139
CTF60C5CGS1+ furnace: Z8ES120C16LMPS1AHRI reference: 21678584315.207.80258002.20EPA 4572144
CTM60C5CGS1+ furnace: Z8ES120C16LMPS1AHRI reference: 21678582915.207.80258002.26EPA 4572149

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →