Johnson Controls / AIR-SOURCE HEAT PUMP

XH536E2S11

LX SERIES · source records, page 6

146 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity32,400–35,000BTU/h

Each efficiency range summarizes published EPA records for XH536E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 146 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16146 / 146
EER2 · BTU/Wh10–12146 / 146
HSPF2 · BTU/Wh7.8–8.1146 / 146
Cooling capacity · BTU/h32,400–35,000146 / 146
Heating capacity at 47°F / 8.3°C · BTU/h30,600–32,800146 / 146
Heating capacity at 17°F / −8.3°C · BTU/h20,400–22,000146 / 146
Heating capacity at 5°F / −15°C · BTU/h17,000–18,400146 / 146
COP at 5°F / −15°C2–2.44146 / 146
Equipment / loop typeHP - Split System146 / 146
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)146 / 146
Compressor stagingTwo-stage146 / 146
Connected capabilityNo146 / 146

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF36C5CDS1+ furnace: Z8ET100C16LMPS1AHRI reference: 21574309215.208.10180002.40EPA 4046917 →
CTF48C5CFS1+ furnace: Z9ET100C16SMPS1AHRI reference: 21637687215.208.10178002.36EPA 4046920 →
CTU48C5XFS1+TXV+ furnace: Z9ET100C16SMPS1AHRI reference: 21637690115.208.10178002.36EPA 4046924 →
CTF48C5CFS1+ furnace: Z9ET080C16SMPS1AHRI reference: 21637693015.208.10183002.32EPA 4046931 →
CTM36C5CDS1+ furnace: Z9ES080C20SMPS1AHRI reference: 21460516815.208.10181002.36EPA 4046934 →
CTF36C5CDS1+ furnace: Z8ES080C20LMPS1AHRI reference: 21678590115.208.10179002.00EPA 4046937 →
CTM36C5CDS1+ furnace: Z8ES080C20LMPS1AHRI reference: 21678591615.208.10179002.40EPA 4046941 →
CTF36C5CDS1+ furnace: Z8ES100C16LMPS1AHRI reference: 21678596115.208.10179002.00EPA 4046947 →
CTU48C5XFS1+TXV+ furnace: Z9ET080C16SMPS1AHRI reference: 21637695915.208.10183002.32EPA 4046952 →
CTM36C5CDS1+ furnace: Z8ET100C16LMPS1AHRI reference: 21643765015.208.10176002.40EPA 4046963 →
CTM48C5CFS1+ furnace: Z8ES080C20SMPS1AHRI reference: 21460538815.208.10179002.38EPA 4046968 →
CTM36C5CDS1+ furnace: Z8ES100C16SMPS1AHRI reference: 21460549815.208.10178002.40EPA 4046973 →
CTM36C5CDS1+ furnace: Z8ES120C16SMPS1AHRI reference: 21460558315.208.10177002.42EPA 4046978 →
CTU48C5XFS1+TXV+ furnace: Z8ES080C20SMPS1AHRI reference: 21480867715.208.10176002.00EPA 4046983 →
CTF36C5CDS1+ furnace: Z8ES120C16SMPS1AHRI reference: 21460561315.208.10173002.00EPA 4046988 →
CTU48C5XFS1+TXV+ furnace: Z9ES080C20SMPS1AHRI reference: 21480870215.208.10178002.00EPA 4046996 →
CTF36C5CDS1+ furnace: Z8ES100C16SMPS1AHRI reference: 21460570315.208.10179002.00EPA 4047002 →
CTF36C5CDS1+ furnace: Z8ES120C20SMPS1AHRI reference: 21460571815.208.10176002.00EPA 4047007 →
CTF48C5CFS1+ furnace: Z8ES080C20SMPS1AHRI reference: 21460574815.208.10176002.00EPA 4047014 →
CTM36C5CDS1+ furnace: Z8ES120C20LMPS1AHRI reference: 21678201015.208.10180002.36EPA 4047015 →