Johnson Controls / AIR-SOURCE HEAT PUMP

XH536E2S11

LX SERIES · source records, page 3

146 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity32,400–35,000BTU/h

Each efficiency range summarizes published EPA records for XH536E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 146 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16146 / 146
EER2 · BTU/Wh10–12146 / 146
HSPF2 · BTU/Wh7.8–8.1146 / 146
Cooling capacity · BTU/h32,400–35,000146 / 146
Heating capacity at 47°F / 8.3°C · BTU/h30,600–32,800146 / 146
Heating capacity at 17°F / −8.3°C · BTU/h20,400–22,000146 / 146
Heating capacity at 5°F / −15°C · BTU/h17,000–18,400146 / 146
COP at 5°F / −15°C2–2.44146 / 146
Equipment / loop typeHP - Split System146 / 146
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)146 / 146
Compressor stagingTwo-stage146 / 146
Connected capabilityNo146 / 146

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM36C5CDS1+JME12C2SN1AHRI reference: 21443162415.208.10176002.42EPA 3559177
CTF36C5CDS1+JMC17C2SN1AHRI reference: 21443169315.208.10171002.00EPA 3559182
CTF36B5CDS1+JME12B2SN1AHRI reference: 21443171815.208.10174002.00EPA 3559187
CTF36C5CDS1+JME16C2SN1AHRI reference: 21443175215.208.10173002.00EPA 3559192
CTF48C5CFS1+ furnace: Z9ES080C16SMPS1AHRI reference: 21460513815.207.80172002.00EPA 3559201
CTM48C5CFS1+ furnace: Z8ES100C16SMPS1AHRI reference: 21460529815.208.10178002.40EPA 3559206
CTF36C5CDS1+ furnace: Z8ES080C16SMPS1AHRI reference: 21460537315.208.10171002.00EPA 3559211
CTM48C5CFS1+ furnace: Z8ES120C16SMPS1AHRI reference: 21460567815.208.10177002.40EPA 3559213
CTF48C5CFS1+ furnace: Z8ES100C16SMPS1AHRI reference: 21460575315.208.10175002.00EPA 3559218
CTU36B5XDS1+JMVT12BC2N1+TXVAHRI reference: 21480822915.207.80171002.00EPA 3559964
CTU36B5XDS1+JMC12B2SN1+TXVAHRI reference: 21480823415.208.10177002.00EPA 3559969
CTU36B5XDS1+JME12B2SN1+TXVAHRI reference: 21480823915.208.10174002.00EPA 3559974
CTU48C5XFS1+JMET16CS2N1+TXVAHRI reference: 21480854715.208.10173002.00EPA 3559979
CTU48C5XFS1+JMC16C2SN1+TXVAHRI reference: 21480855215.208.10172002.00EPA 3559984
CTU48C5XFS1+JMC17C2SN1+TXVAHRI reference: 21480856915.208.10173002.00EPA 3559989
CTU48C5XFS1+JME12C2SN1+TXVAHRI reference: 21480857415.208.10173002.00EPA 3559994
CTU48C5XFS1+TXV+ furnace: Z8ES120C16SMPS1AHRI reference: 21480857915.208.10174002.00EPA 3559998
CTU48C5XFS1+JME16C2SN1+TXVAHRI reference: 21480858415.208.10174002.00EPA 3560039
CTU48C5XFS1+JMET12CS2N1+TXVAHRI reference: 21480866215.208.10173002.00EPA 3560045
CTU48C5XFS1+TXV+ furnace: TL8E100C20UH11AHRI reference: 21480867215.207.80173002.00EPA 3560049

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →