Johnson Controls / AIR-SOURCE HEAT PUMP

XH536E2S11

LX SERIES

146 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity32,400–35,000BTU/h

Each efficiency range summarizes published EPA records for XH536E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 146 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16146 / 146
EER2 · BTU/Wh10–12146 / 146
HSPF2 · BTU/Wh7.8–8.1146 / 146
Cooling capacity · BTU/h32,400–35,000146 / 146
Heating capacity at 47°F / 8.3°C · BTU/h30,600–32,800146 / 146
Heating capacity at 17°F / −8.3°C · BTU/h20,400–22,000146 / 146
Heating capacity at 5°F / −15°C · BTU/h17,000–18,400146 / 146
COP at 5°F / −15°C2–2.44146 / 146
Equipment / loop typeHP - Split System146 / 146
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)146 / 146
Compressor stagingTwo-stage146 / 146
Connected capabilityNo146 / 146

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF48C5CFS1+ furnace: Z8VT080C16SMPC1AHRI reference: 21744474016.008.10180002.40EPA 4044545
CTM48C5CFS1+ furnace: Z8VT080C16SMPC1AHRI reference: 21744473816.008.10180002.40EPA 4044546
CTU48C5XFS1+TXV+ furnace: Z8VT080C16SMPC1AHRI reference: 21744474116.008.10180002.40EPA 4044547
CTM48C5CFS1+ furnace: Z8VT100C16SMPC1AHRI reference: 21744473916.008.10179002.40EPA 4044548
CTU48C5XFS1+TXV+ furnace: Z8VT100C16SMPC1AHRI reference: 21744474316.008.10181002.38EPA 4044549
CTF48C5CFS1+ furnace: Z8VT100C16SMPC1AHRI reference: 21744474216.008.10181002.38EPA 4044551
JHC42C5CF2SS1AHRI reference: 21442563915.208.10175002.00EPA 3558346
CTM48C5CFS1+JMVT17CC2N1AHRI reference: 21442564915.208.10175002.44EPA 3558351
CTM48C5CFS1+JMVT16CC2N1AHRI reference: 21442565915.208.10175002.42EPA 3558356
CTF48C5CFS1+JMVT17CC2N1AHRI reference: 21442566915.208.10172002.00EPA 3558361
CTF48C5CFS1+JMVT16CC2N1AHRI reference: 21442567915.208.10175002.00EPA 3558366
CTF36C5CDS1+JMVT16CC2N1AHRI reference: 21442741315.208.10174002.00EPA 3558565
JHE42C5CF2SS1AHRI reference: 21442563015.208.10173002.00EPA 3558810
CTF36C5CDS1+JME12C2SN1AHRI reference: 21443179215.208.10172002.00EPA 3558814
CTM36C5CDS1+JMC16C2SN1AHRI reference: 21443199115.208.10176002.44EPA 3558828
CTM36C5CDS1+JMVT17CC2N1AHRI reference: 21443201015.208.10177002.44EPA 3558829
CTM36C5CDS1+JMVT16CC2N1AHRI reference: 21443204215.208.10176002.44EPA 3558833
CTF48C5CFS1+JMET12CS2N1AHRI reference: 21443150515.208.10173002.00EPA 3558871
CTM48C5CFS1+ furnace: TL8E080C16UH11AHRI reference: 21443151015.207.80172002.00EPA 3558876
CTF48C5CFS1+ furnace: TL8E100C20UH11AHRI reference: 21443152015.207.80173002.00EPA 3558881