Johnson Controls / AIR-SOURCE HEAT PUMP

THF2B60T21

LX SERIES · source records, page 9

185 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity53,000–57,000BTU/h

Each efficiency range summarizes published EPA records for THF2B60T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 185 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16185 / 185
EER2 · BTU/Wh11–12185 / 185
HSPF2 · BTU/Wh7.8–8.1185 / 185
Cooling capacity · BTU/h53,000–57,000185 / 185
Heating capacity at 47°F / 8.3°C · BTU/h54,500–59,500185 / 185
Heating capacity at 17°F / −8.3°C · BTU/h37,400–39,000185 / 185
Heating capacity at 5°F / −15°C · BTU/h29,200–32,800185 / 185
COP at 5°F / −15°C2–2.46185 / 185
Equipment / loop typeHP - Split System185 / 185
Refrigerant / source-reported GWPR-410A (GWP:2088)185 / 185
Compressor stagingTwo-stage185 / 185
Connected capabilityNo185 / 185

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAFD60JBCN1+ furnace: TM9Y120D20MP11AHRI reference: 21085026515.208.10312002.18EPA 4049536 →
XAFD60JBCN1+ furnace: TM9E120D20MP12AHRI reference: 21085026615.208.10314002.20EPA 4049537 →
XAFD60HXXN1+TXV+ furnace: TM9E080C20MP12AHRI reference: 21085026815.208.10312002.20EPA 4049538 →
XAFD60HBCN1+ furnace: TM8Y120C20MP11AHRI reference: 21085041615.208.10314002.22EPA 4049543 →
XAHD60HBCN1+ furnace: TM9E080C20MP12AHRI reference: 21085051615.208.10308002.02EPA 4049547 →
XAFC60HBCN1+ furnace: Z8ES120C16LMPS1AHRI reference: 21247852315.208.10318002.32EPA 4049551 →
XAFD60HXXN1+TXV+ furnace: Z8ES120C16LMPS1AHRI reference: 21248377415.208.10318002.32EPA 4049563 →
XAFD60HBCN1+ furnace: Z8ES120C16LMPS1AHRI reference: 21248380015.208.10318002.32EPA 4049570 →
XAHD60JXXN1+TXV+ furnace: TM9V120D20MP12AHRI reference: 21084780215.208.10300002.02EPA 4049587 →
XAHD60JBCN1+ furnace: TM8Y100C20MP11AHRI reference: 21084801015.208.10308002.02EPA 4049591 →
XAHD60JXXN1+TXV+ furnace: TM9E100C20MP12AHRI reference: 21084804015.208.10300002.00EPA 4049593 →
XAFC60HXXN1+TXV+ furnace: TM9Y100C20MP11AHRI reference: 21084804315.208.10316002.22EPA 4049595 →
XAFD60HXXN1+TXV+ furnace: TM9E120D20MP12AHRI reference: 21084804415.208.10314002.20EPA 4049596 →
XAFC60HBCN1+ furnace: TM8Y120C20MP11AHRI reference: 21084804515.208.10314002.22EPA 4049597 →
XAHC60HBCN1+ furnace: TM8Y120C20MP11AHRI reference: 21084813115.208.10308002.02EPA 4049598 →
XAHC60HBCN1+ furnace: TM8V120C20MP12AHRI reference: 21084813215.208.10308002.02EPA 4049599 →
XAFD60JBCN1+ furnace: Z8ES100C16SMPS1AHRI reference: 21241523615.208.10314002.36EPA 4049604 →
XAFD60JXXN1+TXV+ furnace: Z8ES080C20SMPS1AHRI reference: 21241525115.208.10314002.38EPA 4049609 →
XAFD60JXXN1+TXV+ furnace: Z8ES100C20LMPS1AHRI reference: 21248497715.208.10314002.38EPA 4049619 →
XAFD60JBCN1+ furnace: Z8ES100C20LMPS1AHRI reference: 21248498415.208.10314002.38EPA 4049623 →