THF2B48T21
LX SERIES · source records, page 5
322 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for THF2B48T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 322 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 322 / 322 |
| EER2 · BTU/Wh | 11–12 | 322 / 322 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 322 / 322 |
| Cooling capacity · BTU/h | 44,500–47,500 | 322 / 322 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 43,500–47,500 | 322 / 322 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–34,200 | 322 / 322 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,400–29,800 | 322 / 322 |
| COP at 5°F / −15°C | 2.22–2.84 | 322 / 322 |
| Equipment / loop type | HP - Split System | 322 / 322 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 322 / 322 |
| Compressor staging | Two-stage | 322 / 322 |
| Connected capability | No | 322 / 322 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
JHETD60HBCS2N1AHRI reference: 211755661 | 16.00 | 8.10 | 23800 | 2.30 | EPA 3558155 → |
JHVTD60HBCC2N1AHRI reference: 211755677 | 16.00 | 8.10 | 23600 | 2.32 | EPA 3558168 → |
XAHC60GBCN1+ furnace: TL8E100C20UH11AHRI reference: 210847161 | 16.00 | 7.80 | 24000 | 2.24 | EPA 3989163 → |
XAHC60HBCN1+ furnace: TM9E080C16MP12AHRI reference: 210850386 | 16.00 | 8.10 | 25000 | 2.46 | EPA 3989281 → |
XAHD60HBCN1+ furnace: TM8V120C20MP12AHRI reference: 210851429 | 16.00 | 8.10 | 24800 | 2.46 | EPA 3989318 → |
XAHC60HBCN1+ furnace: TM8V080C16MP12AHRI reference: 210845194 | 16.00 | 8.10 | 24600 | 2.48 | EPA 3989333 → |
XAHC60HBCN1+JMVT16CC2N1AHRI reference: 210845400 | 16.00 | 8.10 | 25000 | 2.46 | EPA 3989372 → |
XAHC60HBCN1+ furnace: TP9C080C16MP13AHRI reference: 210848809 | 16.00 | 7.80 | 25000 | 2.44 | EPA 3989389 → |
XAHD60HBCN1+ furnace: TM9Y120D20MP11AHRI reference: 210850480 | 16.00 | 8.10 | 25000 | 2.46 | EPA 3989423 → |
XAHC60HBCN1+ furnace: TM9V100C16MP12AHRI reference: 210850482 | 16.00 | 8.10 | 24600 | 2.46 | EPA 3989424 → |
XAFD60HBCN1+JMET18DS2N1AHRI reference: 210850491 | 16.00 | 8.10 | 23800 | 2.30 | EPA 3989430 → |
XAHD60HBCN1+JMET18DS2N1AHRI reference: 210848217 | 16.00 | 8.10 | 25200 | 2.46 | EPA 3989442 → |
XAHC60HBCN1+ furnace: TM9V080C16MP12AHRI reference: 210850231 | 16.00 | 7.80 | 25000 | 2.44 | EPA 3989466 → |
XAHC60HBCN1+ furnace: TP9C100C16MP13AHRI reference: 210849187 | 16.00 | 8.10 | 24600 | 2.46 | EPA 3989542 → |
XAHD60HBCN1+ furnace: TM9V120D20MP12AHRI reference: 210849283 | 16.00 | 8.10 | 25000 | 2.46 | EPA 3989568 → |
XAHC60HBCN1+ furnace: TL8E080C16UH11AHRI reference: 210849290 | 16.00 | 8.10 | 24600 | 2.44 | EPA 3989571 → |
XAHD60HBCN1+JMVT20DC2N1AHRI reference: 210849391 | 16.00 | 8.10 | 25200 | 2.44 | EPA 3989596 → |
XAHD60HBCN1+ furnace: TL9E100C20UH11AHRI reference: 210847174 | 16.00 | 8.10 | 25000 | 2.44 | EPA 3989625 → |
XAHC60HBCN1+ furnace: TL9E080C16UH11AHRI reference: 210847175 | 16.00 | 8.10 | 25000 | 2.46 | EPA 3989627 → |
XAHC60HBCN1+JMVT17CC2N1AHRI reference: 210847767 | 16.00 | 8.10 | 25000 | 2.46 | EPA 3989674 → |