Johnson Controls / AIR-SOURCE HEAT PUMP

THF2B48T21

LX SERIES · source records, page 2

322 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity44,500–47,500BTU/h

Each efficiency range summarizes published EPA records for THF2B48T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 322 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16322 / 322
EER2 · BTU/Wh11–12322 / 322
HSPF2 · BTU/Wh7.8–8.1322 / 322
Cooling capacity · BTU/h44,500–47,500322 / 322
Heating capacity at 47°F / 8.3°C · BTU/h43,500–47,500322 / 322
Heating capacity at 17°F / −8.3°C · BTU/h29,200–34,200322 / 322
Heating capacity at 5°F / −15°C · BTU/h23,400–29,800322 / 322
COP at 5°F / −15°C2.22–2.84322 / 322
Equipment / loop typeHP - Split System322 / 322
Refrigerant / source-reported GWPR-410A (GWP:2088)322 / 322
Compressor stagingTwo-stage322 / 322
Connected capabilityNo322 / 322

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAHC60HBCN1+ furnace: Z8ES100C20LMPS1AHRI reference: 21247862916.008.10244002.40EPA 2483560
XAHC60HBCN1+ furnace: Z8ET080C16LMPS1AHRI reference: 21241364316.008.10244002.40EPA 2483765
XAHC60GBCN1+ furnace: Z8ES080C16SMPS1AHRI reference: 21241747416.008.10250002.36EPA 2484351
XAHD60HBCN1+ furnace: Z8ET100C20LMPS1AHRI reference: 21241805116.008.10244002.38EPA 2484359
XAHD60GBCN1+ furnace: Z8ES130D20SMPS1AHRI reference: 21241716416.008.10254002.36EPA 2484601
XAHC60GBCN1+ furnace: Z8ES120C20SMPS1AHRI reference: 21241719916.007.80250002.34EPA 2484610
XAHD60GBCN1+ furnace: Z8ES080C16LMPS1AHRI reference: 21247604816.007.80250002.36EPA 2484703
XAHC60GBCN1+ furnace: Z8ES120C16SMPS1AHRI reference: 21241724916.008.10252002.36EPA 2484936
XAHC60HBCN1+ furnace: Z8ES080C16LMPS1AHRI reference: 21248372716.008.10244002.40EPA 2485049
XAHC60HBCN1+ furnace: Z8ES080C20SMPS1AHRI reference: 21241393316.008.10244002.40EPA 2485233
XAHD60GBCN1+ furnace: Z8ES100C20SMPS1AHRI reference: 21241728916.007.80252002.34EPA 2485242
XAHC60HBCN1+ furnace: Z8ES080C20LMPS1AHRI reference: 21248650016.008.10244002.40EPA 2485371
XAHC60GBCN1+ furnace: Z8ET100C16LMPS1AHRI reference: 21241704916.007.80254002.34EPA 2485891
XAHC60HBCN1+ furnace: Z8ES100C20SMPS1AHRI reference: 21241382316.008.10244002.40EPA 2485898
XAHD60GBCN1+ furnace: Z8ET080C16LMPS1AHRI reference: 21241708916.007.80248002.36EPA 2485901
XAHC60HBCN1+ furnace: TMLV120C20MP12AHRI reference: 21084686416.008.10250002.46EPA 3025913
XAHC60HBCN1+ furnace: TM8E080B12MP11AHRI reference: 21085152916.007.80250002.44EPA 3026048
XAHC60HBCN1+ furnace: TM8E100C20MP11AHRI reference: 21085114816.008.10254002.44EPA 3026050
XAHD60HBCN1+ furnace: TMLE100C16MP11AHRI reference: 21085172416.008.10250002.46EPA 3026051
XAHC60HBCN1+ furnace: TM8E080C20MP11AHRI reference: 21085131016.008.10254002.44EPA 3026052

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.