Johnson Controls / AIR-SOURCE HEAT PUMP

THF2B42T21

LX SERIES · source records, page 2

419 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity39,500–42,000BTU/h

Each efficiency range summarizes published EPA records for THF2B42T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 419 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16419 / 419
EER2 · BTU/Wh11.7–12419 / 419
HSPF2 · BTU/Wh7.8–8.1419 / 419
Cooling capacity · BTU/h39,500–42,000419 / 419
Heating capacity at 47°F / 8.3°C · BTU/h37,400–41,000419 / 419
Heating capacity at 17°F / −8.3°C · BTU/h24,200–26,600419 / 419
Heating capacity at 5°F / −15°C · BTU/h18,400–22,600419 / 419
COP at 5°F / −15°C1.98–2.42419 / 419
Equipment / loop typeHP - Split System419 / 419
Refrigerant / source-reported GWPR-410A (GWP:2088)419 / 419
Compressor stagingTwo-stage419 / 419
Connected capabilityNo419 / 419

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAHD48FBCN1+ furnace: Z8ES080C20SMPS1AHRI reference: 21241630916.008.10222002.36EPA 2479960 →
XAHC48FBCN1+ furnace: Z9ES100C20SMPS1AHRI reference: 21241561716.008.10222002.32EPA 2481622 →
XAHD48FBCN1+ furnace: Z8ES120C16SMPS1AHRI reference: 21241614916.008.10220002.36EPA 2481654 →
XAHC48FBCN1+ furnace: Z8ES120C16SMPS1AHRI reference: 21241615916.008.10224002.36EPA 2481666 →
XAFC48FBCN1+ furnace: Z8ES120C16SMPS1AHRI reference: 21241617916.008.10214002.22EPA 2481690 →
XAFD48FBCN1+ furnace: Z8ES080C16SMPS1AHRI reference: 21241637416.008.10212002.24EPA 2481899 →
XAFC48FBCN1+ furnace: Z8ES080C16SMPS1AHRI reference: 21241638416.008.10212002.24EPA 2481906 →
XAHC48FBCN1+ furnace: Z8ES080B12SMPS1AHRI reference: 21241639916.008.10220002.34EPA 2481916 →
XAFC48FXXN1+TXV+ furnace: Z8ET080C16LMPS1AHRI reference: 21241603916.008.10210002.24EPA 2481977 →
XAHC48FBCN1+ furnace: Z8ES120C20LMPS1AHRI reference: 21248629016.008.10222002.34EPA 2482474 →
XAFC48FXXN1+TXV+ furnace: Z8ES120C16LMPS1AHRI reference: 21248629716.008.10214002.22EPA 2482480 →
XAFC48FBCN1+ furnace: Z8ES120C16LMPS1AHRI reference: 21248630416.008.10214002.22EPA 2482489 →
XAHC48FBCN1+ furnace: Z8ES100C20LMPS1AHRI reference: 21248871916.008.10222002.36EPA 2482539 →
XAFD48FBCN1+ furnace: Z8ES130D20LMPS1AHRI reference: 21247757616.008.10208002.24EPA 2483515 →
XAHC48FBCN1+ furnace: Z8ES080C16LMPS1AHRI reference: 21248307616.008.10222002.38EPA 2483583 →
XAHC48FBCN1+ furnace: Z8ES080C20LMPS1AHRI reference: 21248633916.008.10222002.36EPA 2483591 →
XAFC48FXXN1+TXV+ furnace: Z8ES080C16LMPS1AHRI reference: 21248634616.008.10212002.24EPA 2483593 →
XAHC48FBCN1+ furnace: Z8ES100C16LMPS1AHRI reference: 21248632516.008.10222002.36EPA 2483594 →
XAFC48FBCN1+ furnace: Z8ES080C16LMPS1AHRI reference: 21248635316.008.10212002.24EPA 2483601 →
XAHD48FBCN1+ furnace: Z8ES120C20SMPS1AHRI reference: 21241610416.008.10222002.34EPA 2483748 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →