Johnson Controls / AIR-SOURCE HEAT PUMP

THF2B36T21

LX SERIES · source records, page 7

215 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity33,400–36,000BTU/h

Each efficiency range summarizes published EPA records for THF2B36T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 215 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16215 / 215
EER2 · BTU/Wh11.7–12215 / 215
HSPF2 · BTU/Wh7.8–8.1215 / 215
Cooling capacity · BTU/h33,400–36,000215 / 215
Heating capacity at 47°F / 8.3°C · BTU/h32,600–34,800215 / 215
Heating capacity at 17°F / −8.3°C · BTU/h21,400–23,800215 / 215
Heating capacity at 5°F / −15°C · BTU/h16,500–20,000215 / 215
COP at 5°F / −15°C1.96–2.44215 / 215
Equipment / loop typeHP - Split System215 / 215
Refrigerant / source-reported GWPR-410A (GWP:2088)215 / 215
Compressor stagingTwo-stage215 / 215
Connected capabilityNo215 / 215

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAFC36DBCN1+ furnace: TM8Y080C16MP11AHRI reference: 21084920115.207.80168001.98EPA 3989551
XAHD48FBCN1+ furnace: TM9Y080C16MP11AHRI reference: 21084924015.207.80178002.04EPA 3989558
XAHD48FBCN1+ furnace: TP9C120D20MP13AHRI reference: 21084924115.207.80174002.10EPA 3989559
XAHC36DBCN1+JMET12CS2N1AHRI reference: 21084923915.207.80172002.10EPA 3989560
XAHC36DBCN1+ furnace: TL8E100C20UH11AHRI reference: 21084929815.207.80176002.08EPA 3989570
XAHC48FBCN1+ furnace: TM9V080C16MP12AHRI reference: 21084933115.207.80176002.04EPA 3989579
XAHC36DBCN1+JMVT16CC2N1AHRI reference: 21084932815.208.10174002.10EPA 3989580
XAHC36DBCN1+ furnace: TM8V080C16MP12AHRI reference: 21085004315.207.80176002.06EPA 3989605
XAHD48FBCN1+ furnace: TP9C100C20MP13AHRI reference: 21085009115.207.80178002.08EPA 3989608
XAFC48FBCN1+ furnace: TL8E100C20UH11AHRI reference: 21085009615.207.80176002.04EPA 3989610
XAHC48FBCN1+ furnace: TM8V080C16MP12AHRI reference: 21085018415.207.80174002.08EPA 3989621
XAHC36DBCN1+ furnace: TM9E100C16MP12AHRI reference: 21084718215.207.80176002.08EPA 3989630
XAHC36DBCN1+ furnace: TP9C100C16MP13AHRI reference: 21084757415.207.80174002.08EPA 3989641
XAHC48FBCN1+ furnace: TM9V080B12MP12AHRI reference: 21084770615.207.80175002.06EPA 3989652
XAFD48FBCN1+ furnace: TL8E100C20UH11AHRI reference: 21084771415.207.80177002.04EPA 3989657
XAFC48FBCN1+JMET12CS2N1AHRI reference: 21084783515.208.10176002.04EPA 3989688
XAHC48FBCN1+ furnace: TL9E060B12UH11AHRI reference: 21084783415.207.80174002.06EPA 3989689
XAFC36DBCN1+ furnace: TL8E100C20UH11AHRI reference: 21084789215.207.80168001.96EPA 3989698
XAHC48FBCN1+ furnace: TM9Y100C16MP11AHRI reference: 21084794815.207.80178002.04EPA 3989707
XAFC36DBCN1+JMET12CS2N1AHRI reference: 21084794715.207.80168002.00EPA 3989708

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →