THF2B30T21
LX SERIES · source records, page 9
246 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for THF2B30T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 246 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 246 / 246 |
| EER2 · BTU/Wh | 11.7–12 | 246 / 246 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 246 / 246 |
| Cooling capacity · BTU/h | 28,400–30,600 | 246 / 246 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 27,000–29,200 | 246 / 246 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 17,500–19,100 | 246 / 246 |
| Heating capacity at 5°F / −15°C · BTU/h | 13,600–18,600 | 246 / 246 |
| COP at 5°F / −15°C | 2.02–2.76 | 246 / 246 |
| Equipment / loop type | HP - Split System | 246 / 246 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 246 / 246 |
| Compressor staging | Two-stage | 246 / 246 |
| Connected capability | No | 246 / 246 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
XAFC36DBAN1+ furnace: TP9C100C16MP13AHRI reference: 210850048 | 15.20 | 7.80 | 14400 | 2.14 | EPA 2838019 → |
XAFC48FBAN1+ furnace: TPLC100C16MP13AHRI reference: 210851382 | 15.20 | 8.10 | 14600 | 2.14 | EPA 2838038 → |
XAFD48FBAN1+ furnace: TMLE120C16MP11AHRI reference: 210851680 | 15.20 | 7.80 | 14000 | 2.12 | EPA 2838059 → |
XAFB36DBAN1+ furnace: TMLV060A12MP12AHRI reference: 210850145 | 15.20 | 7.80 | 14600 | 2.08 | EPA 2838088 → |
XAHD48FBAN1+ furnace: TM8E120C16MP11AHRI reference: 210850197 | 15.20 | 7.80 | 13600 | 2.04 | EPA 2838097 → |
XAFD48FBAN1+ furnace: TM8V080C16MP12AHRI reference: 210850196 | 15.20 | 8.10 | 14600 | 2.14 | EPA 2838101 → |
XAFC48FBAN1+ furnace: TMLE100C16MP11AHRI reference: 210850198 | 15.20 | 7.80 | 14000 | 2.10 | EPA 2838103 → |
XAFC36DBAN1+ furnace: TM9V080B12MP12AHRI reference: 210850254 | 15.20 | 7.80 | 14500 | 2.12 | EPA 2838108 → |
XAFC36DBAN1+ furnace: TM9V080C16MP12AHRI reference: 210851449 | 15.20 | 7.80 | 14500 | 2.06 | EPA 2838139 → |
XAHC36DBAN1+ furnace: TM8Y120C20MP11AHRI reference: 210847669 | 15.20 | 7.80 | 13800 | 2.06 | EPA 3558058 → |
XAHC36DBAN1+ furnace: TM8Y100C20MP11AHRI reference: 210848944 | 15.20 | 7.80 | 13800 | 2.06 | EPA 3558074 → |
XAFC36DBAN1+JME12C2SN1AHRI reference: 214801951 | 15.20 | 8.10 | 16500 | 2.50 | EPA 3559219 → |
XAFC36DBAN1+JMC16C2SN1AHRI reference: 214801972 | 15.20 | 8.10 | 18400 | 2.76 | EPA 3559257 → |
XAFB36DBAN1+JMC12B2SN1AHRI reference: 214801974 | 15.20 | 8.10 | 18000 | 2.66 | EPA 3559259 → |
XAFC36DBAN1+JMC17C2SN1AHRI reference: 214801976 | 15.20 | 8.10 | 17600 | 2.68 | EPA 3559261 → |
XAFC36DBAN1+JME16C2SN1AHRI reference: 214801947 | 15.20 | 8.10 | 17900 | 2.68 | EPA 3559693 → |
XAFB36DBAN1+JME12B2SN1AHRI reference: 214801949 | 15.20 | 8.10 | 18600 | 2.74 | EPA 3559697 → |
XAFC48FBAN1+JME12C2SN1AHRI reference: 214811081 | 15.20 | 8.10 | 15800 | 2.42 | EPA 3560457 → |
XAFC48FBAN1+JMC17C2SN1AHRI reference: 214811083 | 15.20 | 8.10 | 15600 | 2.40 | EPA 3560459 → |
XAFD48FBAN1+JME18D2SN1AHRI reference: 214811085 | 15.20 | 8.10 | 15600 | 2.40 | EPA 3560461 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →