Johnson Controls / AIR-SOURCE HEAT PUMP

THF2B30T21

LX SERIES · source records, page 3

246 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity28,400–30,600BTU/h

Each efficiency range summarizes published EPA records for THF2B30T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 246 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16246 / 246
EER2 · BTU/Wh11.7–12246 / 246
HSPF2 · BTU/Wh7.8–8.1246 / 246
Cooling capacity · BTU/h28,400–30,600246 / 246
Heating capacity at 47°F / 8.3°C · BTU/h27,000–29,200246 / 246
Heating capacity at 17°F / −8.3°C · BTU/h17,500–19,100246 / 246
Heating capacity at 5°F / −15°C · BTU/h13,600–18,600246 / 246
COP at 5°F / −15°C2.02–2.76246 / 246
Equipment / loop typeHP - Split System246 / 246
Refrigerant / source-reported GWPR-410A (GWP:2088)246 / 246
Compressor stagingTwo-stage246 / 246
Connected capabilityNo246 / 246

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAFC36DBAN1+JMVT17CC2N1AHRI reference: 21084803716.008.10142002.16EPA 2837755
XAHC48FBAN1+ furnace: TM8E080C16MP11AHRI reference: 21084808116.007.80136002.02EPA 2837767
XAFC36DBAN1+ furnace: TM8V080C16MP12AHRI reference: 21084812516.008.10145002.10EPA 2837775
XAFC36DBAN1+ furnace: TMLE080C16MP11AHRI reference: 21084812716.008.10145002.10EPA 2837776
XAFC36DBAN1+ furnace: TMLE100B12MP11AHRI reference: 21084872616.007.80144002.12EPA 2837790
XAHC48FBAN1+ furnace: TMLE120C16MP11AHRI reference: 21085031916.007.80136002.06EPA 2837828
XAFD48FBAN1+ furnace: TM8E080C16MP11AHRI reference: 21085064116.008.10146002.12EPA 2837844
XAFC36DBAN1+ furnace: TPLC080C16MP13AHRI reference: 21085105616.008.10145002.10EPA 2837852
XAFC36DBAN1+ furnace: TM9Y080C16MP11AHRI reference: 21085116416.007.80146002.14EPA 2837858
XAFC36DBAN1+ furnace: TM9E080C16MP12AHRI reference: 21085116716.007.80146002.10EPA 2837860
XAHC48FBAN1+ furnace: TM8E120C16MP11AHRI reference: 21085123016.007.80136002.06EPA 2837876
XAFC36DBAN1+ furnace: TMLE120C16MP11AHRI reference: 21085059616.008.10145002.12EPA 2837911
XAFC36DBAN1+JMET12CS2N1AHRI reference: 21085059916.008.10143002.14EPA 2837912
XAHD48FBAN1+ furnace: TM8Y080C16MP11AHRI reference: 21085110616.007.80137002.04EPA 2837924
XAFC36DBAN1+ furnace: TM9E100C16MP12AHRI reference: 21085041016.007.80146002.10EPA 2837945
XAFB36DBAN1+ furnace: TMLE040A12MP11AHRI reference: 21085133116.007.80146002.08EPA 2837980
XAFC36DBAN1+ furnace: TM8E080C16MP11AHRI reference: 21084930216.008.10145002.10EPA 2837998
XAFC36DBAN1+ furnace: TM8E100C16MP11AHRI reference: 21085154716.008.10145002.12EPA 2838007
XAFC36DBAN1+ furnace: TL8E100C20UH11AHRI reference: 21085005916.008.10143002.12EPA 2838018
XAFC36DBAN1+ furnace: TM8E120C16MP11AHRI reference: 21085163616.008.10145002.12EPA 2838047

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →