Johnson Controls / AIR-SOURCE HEAT PUMP

THF2B30T21

LX SERIES

246 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity28,400–30,600BTU/h

Each efficiency range summarizes published EPA records for THF2B30T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 246 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16246 / 246
EER2 · BTU/Wh11.7–12246 / 246
HSPF2 · BTU/Wh7.8–8.1246 / 246
Cooling capacity · BTU/h28,400–30,600246 / 246
Heating capacity at 47°F / 8.3°C · BTU/h27,000–29,200246 / 246
Heating capacity at 17°F / −8.3°C · BTU/h17,500–19,100246 / 246
Heating capacity at 5°F / −15°C · BTU/h13,600–18,600246 / 246
COP at 5°F / −15°C2.02–2.76246 / 246
Equipment / loop typeHP - Split System246 / 246
Refrigerant / source-reported GWPR-410A (GWP:2088)246 / 246
Compressor stagingTwo-stage246 / 246
Connected capabilityNo246 / 246

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAHC48FBAN1+ furnace: Z8ES080B12SMPS1AHRI reference: 21248550016.007.80144002.16EPA 2474325 →
XAFC48FBAN1+ furnace: Z8ES080B12SMPS1AHRI reference: 21248843416.008.10157002.28EPA 2474397 →
XAFB36DBAN1+ furnace: Z8ES100B12LMPS1AHRI reference: 21248269216.008.10158002.26EPA 2474561 →
XAFC48FBAN1+ furnace: Z8ES100B12SMPS1AHRI reference: 21248610116.008.10158002.28EPA 2474597 →
XAFC48FXXN1+TXV+ furnace: Z8ES100B12LMPS1AHRI reference: 21248609616.008.10158002.28EPA 2474704 →
XAFC48FBAN1+ furnace: Z8ES080B12LMPS1AHRI reference: 21248844616.008.10157002.28EPA 2475107 →
XAFB36DBAN1+ furnace: Z8ES040A12SMPS1AHRI reference: 21247530316.008.10156002.26EPA 2475124 →
XAFC48FXXN1+TXV+ furnace: Z8ES080B12LMPS1AHRI reference: 21248842916.008.10157002.28EPA 2475139 →
XAHC48FBAN1+ furnace: Z8ES100B12LMPS1AHRI reference: 21247800316.007.80145002.18EPA 2476430 →
XAFB36DXXN1+TXV+ furnace: Z8ES060A12SMPS1AHRI reference: 21248272616.007.80152002.24EPA 2477063 →
XAFB36DBAN1+ furnace: Z8ES040A12LMPS1AHRI reference: 21247532716.008.10156002.26EPA 2477493 →
XAFB36DBAN1+ furnace: Z8ES060A12LMPS1AHRI reference: 21248607716.007.80152002.24EPA 2477639 →
XAFB36DXXN1+TXV+ furnace: Z8ES100B12LMPS1AHRI reference: 21248264416.008.10158002.26EPA 2477983 →
XAFB36DBAN1+ furnace: Z8ES100B12SMPS1AHRI reference: 21248266316.008.10158002.26EPA 2478711 →
XAFC48FBAN1+ furnace: Z8ES100B12LMPS1AHRI reference: 21248611316.008.10158002.28EPA 2478722 →
XAFC48FXXN1+TXV+ furnace: Z8ES100B12SMPS1AHRI reference: 21248608916.008.10158002.28EPA 2479680 →
XAFA30DBAN1+ furnace: Z8ES060A12SMPS1AHRI reference: 21248547616.007.80153002.22EPA 2480455 →
XAHC48FBAN1+ furnace: Z8ES100B12SMPS1AHRI reference: 21247799616.007.80145002.18EPA 2480671 →
XAFC48FXXN1+TXV+ furnace: Z8ES080B12SMPS1AHRI reference: 21248842216.008.10157002.28EPA 2480720 →
XAHC48FBAN1+ furnace: Z8ES080B12LMPS1AHRI reference: 21248550716.007.80144002.16EPA 2481178 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →