HMH72B341
HMH7 · source records, page 25
844 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HMH72B341. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 844 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–18.5 | 844 / 844 |
| EER2 · BTU/Wh | 8.5–10.5 | 844 / 844 |
| HSPF2 · BTU/Wh | 8.1–8.5 | 844 / 844 |
| Cooling capacity · BTU/h | 31,400–35,200 | 844 / 844 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,400–35,200 | 844 / 844 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,200–27,000 | 844 / 844 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,200–25,000 | 844 / 844 |
| COP at 5°F / −15°C | 1.8–2.18 | 844 / 844 |
| Equipment / loop type | HP - Split System | 844 / 844 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 844 / 844 |
| Compressor staging | Continuously variable | 844 / 844 |
| Connected capability | No | 844 / 844 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
XAHD48FBCN1+ furnace: TM9Y080C16MP11Cold climate designationAHRI reference: 211394013 | 17.00 | 8.10 | 23200 | 2.02 | EPA 2482887 → |
XAHC48FXXN1+TXV+ furnace: TM9Y080C16MP11Cold climate designationAHRI reference: 211394028 | 17.00 | 8.10 | 23600 | 2.02 | EPA 2482890 → |
XAFD48FBCN1+ furnace: TMLE080C16MP11Cold climate designationAHRI reference: 211385826 | 17.00 | 8.50 | 23400 | 2.06 | EPA 2483097 → |
XAFC48FXXN1+TXV+ furnace: TM8E080C16MP11Cold climate designationAHRI reference: 211385835 | 17.00 | 8.50 | 23400 | 2.06 | EPA 2483102 → |
XAFC48FXXN1+TXV+ furnace: TMLE080C16MP11Cold climate designationAHRI reference: 211385848 | 17.00 | 8.50 | 23400 | 2.06 | EPA 2483103 → |
XAHC48FBCN1+ furnace: TM9Y080C16MP11Cold climate designationAHRI reference: 211394043 | 17.00 | 8.10 | 23600 | 2.02 | EPA 2483111 → |
XAHB36DXXN1+TXV+ furnace: TM9Y060B12MP11Cold climate designationAHRI reference: 211387119 | 17.00 | 8.10 | 23400 | 1.98 | EPA 2483621 → |
XAHB36DBCN1+ furnace: TM9Y060B12MP11Cold climate designationAHRI reference: 211387133 | 17.00 | 8.10 | 23400 | 1.98 | EPA 2483626 → |
XAHB36DBCN1+ furnace: TM9Y080B12MP11Cold climate designationAHRI reference: 211386942 | 17.00 | 8.10 | 23200 | 2.00 | EPA 2483641 → |
XAHC48FBCN1+ furnace: TP9C100C20MP13Cold climate designationAHRI reference: 211394514 | 17.00 | 8.50 | 23400 | 2.04 | EPA 2483652 → |
XAFC36DXXN1+TXV+ furnace: TL9E100C20UH11Cold climate designationAHRI reference: 211393024 | 17.00 | 8.50 | 25000 | 2.12 | EPA 2483952 → |
XAHC36DXXN1+TXV+ furnace: TL9E080C16UH11Cold climate designationAHRI reference: 211393069 | 17.00 | 8.10 | 24000 | 2.06 | EPA 2483954 → |
XAHC36DBCN1+ furnace: TL9E080C16UH11Cold climate designationAHRI reference: 211393075 | 17.00 | 8.10 | 24000 | 2.06 | EPA 2483961 → |
XAFB36DXXN1+TXV+ furnace: TM9V040A10MP12Cold climate designationAHRI reference: 211388508 | 17.00 | 8.10 | 23400 | 2.00 | EPA 2484206 → |
XAFB36DBCN1+ furnace: TM9V040A10MP12Cold climate designationAHRI reference: 211388513 | 17.00 | 8.10 | 23400 | 2.00 | EPA 2484210 → |
XAHC36DBCN1+ furnace: TP9C100C16MP13Cold climate designationAHRI reference: 211387457 | 17.00 | 8.10 | 23600 | 2.06 | EPA 2484218 → |
XAFC48FBCN1+ furnace: TM8E080C16MP11Cold climate designationAHRI reference: 211385861 | 17.00 | 8.50 | 23400 | 2.06 | EPA 2484462 → |
XAFC48FBCN1+ furnace: TMLE080C16MP11Cold climate designationAHRI reference: 211385893 | 17.00 | 8.50 | 23400 | 2.06 | EPA 2484472 → |
XAHC36DXXN1+TXV+ furnace: TM9V080C16MP12Cold climate designationAHRI reference: 211387569 | 17.00 | 8.10 | 23400 | 2.04 | EPA 2484501 → |
XAHC36DBCN1+ furnace: TP9C080C16MP13Cold climate designationAHRI reference: 211387598 | 17.00 | 8.10 | 23400 | 2.04 | EPA 2484504 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →