HL19B2421
MOMENTUM · source records, page 4
85 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HL19B2421. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 85 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–18 | 85 / 85 |
| EER2 · BTU/Wh | 11.7–14 | 85 / 85 |
| HSPF2 · BTU/Wh | 7.8 | 85 / 85 |
| Cooling capacity · BTU/h | 21,200–24,200 | 85 / 85 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,400–23,800 | 85 / 85 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,200–15,200 | 85 / 85 |
| Heating capacity at 5°F / −15°C · BTU/h | 10,900–12,200 | 85 / 85 |
| COP at 5°F / −15°C | 1.8–2.06 | 85 / 85 |
| Equipment / loop type | HP - Split System | 85 / 85 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 85 / 85 |
| Compressor staging | Two-stage | 85 / 85 |
| Connected capability | No | 85 / 85 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
XAFB36DXXN1+TXV+ furnace: Z8ES080B12LMPS1AHRI reference: 212479985 | 17.00 | 7.80 | 10900 | 1.80 | EPA 3990548 → |
XAHB36DBAN1+ furnace: Z8ES100B12SMPS1AHRI reference: 212480474 | 17.00 | 7.80 | 11000 | 1.80 | EPA 3990552 → |
XAHB36DBAN1+ furnace: Z8ES100B12LMPS1AHRI reference: 212480479 | 17.00 | 7.80 | 11000 | 1.80 | EPA 3990560 → |
XAFB36DBAN1+ furnace: Z8ES080B12LMPS1AHRI reference: 212479030 | 17.00 | 7.80 | 10900 | 1.80 | EPA 3990570 → |
XAFA30DBAN1+ furnace: Z8ES040A12LMPS1AHRI reference: 212484597 | 17.00 | 7.80 | 11000 | 1.80 | EPA 3990574 → |
XAHB36DBAN1+ furnace: Z8ES080B12LMPS1AHRI reference: 212488801 | 17.00 | 7.80 | 10900 | 1.80 | EPA 3991100 → |
XAHB36DBAN1+ furnace: TM9V060B12MP12AHRI reference: 210848704 | 16.00 | 7.80 | 11200 | 1.98 | EPA 2477248 → |
XAHB36DBAN1+ furnace: TP9C080B12MP13AHRI reference: 210846488 | 16.00 | 7.80 | 11000 | 2.00 | EPA 2481424 → |
XAHB36DBAN1+ furnace: TM8V080B12MP12AHRI reference: 210847517 | 16.00 | 7.80 | 11200 | 1.98 | EPA 2481431 → |
XAHB36DBAN1+ furnace: TP9C060B12MP13AHRI reference: 210847531 | 16.00 | 7.80 | 11200 | 1.98 | EPA 2481435 → |
XAHB36DBAN1+ furnace: TM9V080B12MP12AHRI reference: 210847534 | 16.00 | 7.80 | 11000 | 2.00 | EPA 2481440 → |
XAHB36DBAN1+ furnace: TM8Y080B12MP11AHRI reference: 210848705 | 16.00 | 7.80 | 10900 | 2.02 | EPA 2481454 → |
XAHB36DBAN1+ furnace: TL9E060B12UH11AHRI reference: 210848699 | 16.00 | 7.80 | 11200 | 2.00 | EPA 2481459 → |
XAHB36DBAN1+ furnace: TM9E026A08MP12AHRI reference: 210851023 | 16.00 | 7.80 | 11100 | 1.96 | EPA 2481484 → |
XAHB36DBAN1+ furnace: TM9E080B12MP12AHRI reference: 210846468 | 16.00 | 7.80 | 11000 | 1.98 | EPA 3989168 → |
XAHB36DBAN1+ furnace: TM9Y080B12MP11AHRI reference: 210846477 | 16.00 | 7.80 | 11000 | 2.00 | EPA 3989169 → |
XAHB36DBAN1+ furnace: TM9Y060B12MP11AHRI reference: 210847520 | 16.00 | 7.80 | 11000 | 2.00 | EPA 3989632 → |
XAHB36DBAN1+ furnace: TM9E060B12MP12AHRI reference: 210851032 | 16.00 | 7.80 | 11400 | 1.98 | EPA 3989780 → |
XAFA30DBAN1+ furnace: Z9ES026A08SMPS1AHRI reference: 211768977 | 16.00 | 7.80 | 11200 | 1.98 | EPA 3990216 → |
XAHB36DBAN1+ furnace: Z9ES060B12SMPS1AHRI reference: 211768985 | 16.00 | 7.80 | 12000 | 2.06 | EPA 3990217 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →