257 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–38,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 257 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17257 / 257
EER2 · BTU/Wh11.7–13257 / 257
HSPF2 · BTU/Wh7.8–8.5257 / 257
Cooling capacity · BTU/h33,800–38,000257 / 257
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000257 / 257
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200257 / 257
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600257 / 257
COP at 5°F / −15°C1.78–2.48257 / 257
Equipment / loop typeHP - Split System257 / 257
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)257 / 257
Compressor stagingTwo-stage257 / 257
Connected capabilityNo257 / 257

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X43M21A*+ furnace: *80MSU0802120A*AHRI reference: 21563779716.008.50191002.40EPA 3955551 →
EA*5X43M21A*+ furnace: *95MSU1002122A*AHRI reference: 21563839716.008.10191002.40EPA 3956025 →
EA*5X43M21A*+ furnace: *96VTN1002122B*AHRI reference: 21563862716.008.10192002.40EPA 3956059 →
EA*5X48M21A*+ furnace: *80MSU0802120A*AHRI reference: 21563889116.008.10190002.40EPA 3956126 →
EA*5X48M21A*+ furnace: *96VTN1002122B*AHRI reference: 21563975116.008.10191002.26EPA 3956447 →
EA*5X37M21A*+ furnace: *80CSU0802120B*AHRI reference: 21572136116.008.00192002.28EPA 3982085 →
EA*5X43M21A*+ furnace: *80CSU0802120B*AHRI reference: 21572152216.008.00192002.40EPA 3982133 →
EA*5X48M21A*+ furnace: *97VTN1002122A*AHRI reference: 21572159616.008.00191002.26EPA 3982203 →
EVM5X49M21A*+ furnace: *97VTN1002120A*AHRI reference: 21571630216.008.00179001.90EPA 3997646 →
EVD5X38M17A*+ furnace: *80CSU0601716B*AHRI reference: 21571670116.008.00175001.82EPA 3997661 →
EVD5X38M17A*+ furnace: *80CSU0401712B*AHRI reference: 21571668716.008.00176001.82EPA 3997675 →
EA*5X37M21A*+ furnace: *97VTN1002122A*AHRI reference: 21571485116.008.50192002.40EPA 3997702 →
QFVA5D3617X*AHRI reference: 21869539516.008.10183002.20EPA 4683432 →
EA*5X43M21A*+ furnace: *96CTN0802120B*AHRI reference: 21563846515.508.00193002.26EPA 3719674 →
EVM5X48M21A*+ furnace: *80CSU0802120A*AHRI reference: 21561945215.507.80176001.78EPA 3946249 →
EVM5X48M21A*+ furnace: *80VSL1102122B*AHRI reference: 21561950515.507.80177001.78EPA 3946281 →
EVM5X48M21A*+ furnace: *80MSU0601716A*AHRI reference: 21561952115.507.80177001.78EPA 3946316 →
EVM5X48M21A*+ furnace: *95CSU1002122B*AHRI reference: 21561967315.507.80178001.78EPA 3946370 →
EVM5X48M21A*+ furnace: *96CTN0802120B*AHRI reference: 21561977215.507.80178001.78EPA 3946435 →
EVD5X38M17A*+ furnace: *80CSU0401712A*AHRI reference: 21562125915.507.80178001.80EPA 3946466 →