N5H8T36*K*AAA*
2-STAGE 18 SEER HP
257 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H8T36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 257 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 257 / 257 |
| EER2 · BTU/Wh | 11.7–13 | 257 / 257 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 257 / 257 |
| Cooling capacity · BTU/h | 33,800–38,000 | 257 / 257 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 37,200–39,000 | 257 / 257 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 23,000–24,200 | 257 / 257 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,500–19,600 | 257 / 257 |
| COP at 5°F / −15°C | 1.78–2.48 | 257 / 257 |
| Equipment / loop type | HP - Split System | 257 / 257 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 257 / 257 |
| Compressor staging | Two-stage | 257 / 257 |
| Connected capability | No | 257 / 257 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FTMA5B60L0D*AHRI reference: 215628950 | 17.00 | 8.50 | 18600 | 2.48 | EPA 3950885 → |
FTMA5B48L0C*AHRI reference: 215628896 | 16.50 | 8.10 | 18700 | 2.30 | EPA 3950437 → |
QFVA5D4821X*AHRI reference: 218695412 | 16.50 | 8.10 | 18400 | 2.24 | EPA 4683415 → |
EVM5X48M21A*+ furnace: *80MSU0802120A*AHRI reference: 215619540 | 16.00 | 8.00 | 17500 | 1.90 | EPA 3946335 → |
EVM5X49M21A*+ furnace: *80VSL0902120B*AHRI reference: 215619888 | 16.00 | 8.00 | 17900 | 1.90 | EPA 3946544 → |
EVM5X49M21A*+ furnace: *80MSU0802120A*AHRI reference: 215619904 | 16.00 | 8.00 | 17700 | 1.95 | EPA 3946559 → |
EVM5X49M21A*+ furnace: *80VTL0902120B*AHRI reference: 215619977 | 16.00 | 8.00 | 17900 | 1.90 | EPA 3946634 → |
EVM5X49M21A*+ furnace: *95CSU1002122B*AHRI reference: 215620004 | 16.00 | 8.00 | 17900 | 1.95 | EPA 3946645 → |
EVM5X49M21A*+ furnace: *96CTN0802120B*AHRI reference: 215620045 | 16.00 | 7.80 | 17900 | 1.80 | EPA 3946662 → |
EVM5X49M21A*+ furnace: *96VTN1002120B*AHRI reference: 215620084 | 16.00 | 8.00 | 17900 | 1.90 | EPA 3946679 → |
EVD5X38M17A*+ furnace: *80VSL0901716B*AHRI reference: 215621313 | 16.00 | 8.00 | 17600 | 1.90 | EPA 3946862 → |
EVD5X38M17A*+ furnace: *80MSU0401712A*AHRI reference: 215621329 | 16.00 | 8.00 | 17600 | 1.85 | EPA 3946881 → |
EVD5X38M17A*+ furnace: *80MSU0601716A*AHRI reference: 215621348 | 16.00 | 8.00 | 17600 | 1.90 | EPA 3946897 → |
EVD5X38M17A*+ furnace: *80CTL0901716B*AHRI reference: 215621406 | 16.00 | 7.80 | 17600 | 1.80 | EPA 3946926 → |
EA*5X37M21A*+ furnace: *80VSL1102122B*AHRI reference: 215635687 | 16.00 | 8.10 | 19400 | 2.24 | EPA 3954583 → |
EA*5X37M21A*+ furnace: *80MSU0601716A*AHRI reference: 215635720 | 16.00 | 8.10 | 19300 | 2.26 | EPA 3954617 → |
EA*5X37M21A*+ furnace: *95MSU1002122A*AHRI reference: 215636144 | 16.00 | 8.10 | 19400 | 2.26 | EPA 3955061 → |
EA*5X37M21A*+ furnace: *96VTN1002122B*AHRI reference: 215636375 | 16.00 | 8.10 | 19200 | 2.40 | EPA 3955137 → |
EA*5X43M21A*+ furnace: *80VSL1102122B*AHRI reference: 215637719 | 16.00 | 8.10 | 19200 | 2.40 | EPA 3955496 → |
EA*5X43M21A*+ furnace: *80MSU0601716A*AHRI reference: 215637769 | 16.00 | 8.10 | 19300 | 2.26 | EPA 3955534 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.