1U60T3PE*HE
Connect · source records, page 2
191 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 1U60T3PE*HE. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 191 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 191 / 191 |
| EER2 · BTU/Wh | 9.6–11.7 | 191 / 191 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 191 / 191 |
| Cooling capacity · BTU/h | 42,500–55,500 | 191 / 191 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,500–56,000 | 191 / 191 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,000–45,000 | 191 / 191 |
| Heating capacity at 5°F / −15°C · BTU/h | 39,000–43,000 | 191 / 191 |
| COP at 5°F / −15°C | 1.75–1.95 | 191 / 191 |
| Equipment / loop type | HP - Split System | 191 / 191 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 191 / 191 |
| Compressor staging | Continuously variable | 191 / 191 |
| Connected capability | No | 191 / 191 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
NCUC49CT5****+TDR+ furnace: NF96U090V5C***Cold climate designationAHRI reference: 217270635 | 17.10 | 9.00 | 39500 | 1.85 | EPA 4027468 → |
NCUC49CT5****+TDR+ furnace: NF97U090V5C***Cold climate designationAHRI reference: 217270270 | 17.10 | 9.00 | 39500 | 1.85 | EPA 4027606 → |
NCUC48CT5****+TDR+ furnace: NF80U110V5C***Cold climate designationAHRI reference: 217270488 | 17.10 | 8.50 | 39500 | 1.80 | EPA 4027815 → |
NCUC49CT5****+TDR+ furnace: NF98U090M5C***Cold climate designationAHRI reference: 217270510 | 17.10 | 9.00 | 39500 | 1.85 | EPA 4027837 → |
NCDC60DT5****+TDR+ furnace: NF80D110S5C***Cold climate designationAHRI reference: 217270573 | 17.05 | 8.50 | 40000 | 1.90 | EPA 4027440 → |
NCUC49CT5****+TDR+ furnace: NF95X080S4C***Cold climate designationAHRI reference: 217270499 | 17.05 | 9.00 | 39500 | 1.85 | EPA 4027826 → |
NCDC42BT5****+TDR+ furnace: NF96D070S4B***Cold climate designationAHRI reference: 217270542 | 17.00 | 9.00 | 39500 | 1.85 | EPA 4027409 → |
NCDC48CT5****+TDR+ furnace: NF97D110M5C***Cold climate designationAHRI reference: 217270546 | 17.00 | 9.00 | 39500 | 1.90 | EPA 4027413 → |
NCUC60CT5****+TDR+ furnace: NF98U110M5C***Cold climate designationAHRI reference: 217270555 | 17.00 | 8.50 | 40000 | 1.90 | EPA 4027422 → |
NCUC49CT5****+TDR+ furnace: NF98U090M4C***Cold climate designationAHRI reference: 217270498 | 17.00 | 9.00 | 39500 | 1.85 | EPA 4027825 → |
NCHC42BT5****+TDR+ furnace: NF80U090S4B***Cold climate designationAHRI reference: 217270517 | 16.95 | 9.00 | 39000 | 1.90 | EPA 4027384 → |
NCHC48BT5****+TDR+ furnace: NF80U090S4B***Cold climate designationAHRI reference: 217270532 | 16.95 | 9.00 | 39500 | 1.85 | EPA 4027399 → |
NCDC42BT5****+TDR+ furnace: NF80D090T4B***Cold climate designationAHRI reference: 217270541 | 16.95 | 9.00 | 39000 | 1.85 | EPA 4027408 → |
NCDC5060CT5****+TDR+ furnace: NF80D110S5C***Cold climate designationAHRI reference: 217270596 | 16.95 | 8.50 | 40000 | 1.90 | EPA 4027482 → |
NCUC48BT5****+TDR+ furnace: NF80U090S4B***Cold climate designationAHRI reference: 217270484 | 16.95 | 8.50 | 39500 | 1.80 | EPA 4027811 → |
NCUC60CT5****+TDR+ furnace: NF96U110V5C***Cold climate designationAHRI reference: 217270642 | 16.90 | 8.50 | 40000 | 1.90 | EPA 4027506 → |
NCUC60CT5****+TDR+ furnace: NF97U110V5C***Cold climate designationAHRI reference: 217270281 | 16.90 | 8.50 | 40000 | 1.90 | EPA 4027618 → |
NCUC48BT5****+TDR+ furnace: NF80U090V4B***Cold climate designationAHRI reference: 217270480 | 16.90 | 8.50 | 39500 | 1.80 | EPA 4027807 → |
NCUC60CT5****+TDR+ furnace: NF80L110S5C***Cold climate designationAHRI reference: 217270551 | 16.85 | 8.50 | 40000 | 1.90 | EPA 4027418 → |
NCUC60CT5****+TDR+ furnace: NF80U110T5C***Cold climate designationAHRI reference: 217270552 | 16.85 | 8.50 | 40000 | 1.90 | EPA 4027419 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →