Haier / AIR-SOURCE HEAT PUMP

1U60T3PE*HE

Connect

191 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range8.1–9.5BTU/Wh
Cooling capacity42,500–55,500BTU/h

Each efficiency range summarizes published EPA records for 1U60T3PE*HE. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 191 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18191 / 191
EER2 · BTU/Wh9.6–11.7191 / 191
HSPF2 · BTU/Wh8.1–9.5191 / 191
Cooling capacity · BTU/h42,500–55,500191 / 191
Heating capacity at 47°F / 8.3°C · BTU/h47,500–56,000191 / 191
Heating capacity at 17°F / −8.3°C · BTU/h38,000–45,000191 / 191
Heating capacity at 5°F / −15°C · BTU/h39,000–43,000191 / 191
COP at 5°F / −15°C1.75–1.95191 / 191
Equipment / loop typeHP - Split System191 / 191
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)191 / 191
Compressor stagingContinuously variable191 / 191
Connected capabilityNo191 / 191

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
NAM48V1TA5****Cold climate designationAHRI reference: 21726959118.009.50420001.75EPA 4027515
NAM42V2TA5****Cold climate designationAHRI reference: 21727018318.009.50425001.85EPA 4027536
NCUC49CT5****+TDR+ furnace: NF80U110V5C***Cold climate designationAHRI reference: 21727050117.659.00390001.85EPA 4027828
NAM42E1TA5****Cold climate designationAHRI reference: 21727018017.609.00430001.80EPA 4027533
NAM42V1TA5****Cold climate designationAHRI reference: 21727018117.609.00430001.80EPA 4027535
NAM48V2TA5****Cold climate designationAHRI reference: 21727018417.509.00430001.80EPA 4027537
NAM48E1TA5****Cold climate designationAHRI reference: 21727018217.509.00430001.80EPA 4027538
NCUC49CT5****+TDR+ furnace: NF80X080V4B***Cold climate designationAHRI reference: 21727050217.459.00390001.85EPA 4027829
NCUC49CT5****+TDR+ furnace: NF80X100V5C***Cold climate designationAHRI reference: 21727050317.459.00390001.85EPA 4027830
NCUC49CT5****+TDR+ furnace: NF98U110M5C***Cold climate designationAHRI reference: 21727050917.409.00390001.85EPA 4027836
NCDC48CT5****+TDR+ furnace: NF96D090S4C***Cold climate designationAHRI reference: 21727054417.259.00390001.90EPA 4027411
NCUC49CT5****+TDR+ furnace: NF97X080V5C***Cold climate designationAHRI reference: 21727026817.259.00395001.85EPA 4027605
NCUC49CT5****+TDR+ furnace: NF96U110V5C***Cold climate designationAHRI reference: 21727063417.209.00395001.85EPA 4027467
NCUC49CT5****+TDR+ furnace: NF97U110V5C***Cold climate designationAHRI reference: 21727026917.209.00395001.85EPA 4027607
NCUC49CT5****+TDR+ furnace: NF80U090S5C***Cold climate designationAHRI reference: 21727050717.209.00395001.85EPA 4027834
NCUC49CT5****+TDR+ furnace: NF80U110S5C***Cold climate designationAHRI reference: 21727050817.209.00395001.85EPA 4027835
NCDC48CT5****+TDR+ furnace: NF80D110S5C***Cold climate designationAHRI reference: 21727054517.159.00390001.90EPA 4027412
NCUC60CT5****+TDR+ furnace: NF80U090S5C***Cold climate designationAHRI reference: 21727055317.158.50405001.90EPA 4027420
NCUC60CT5****+TDR+ furnace: NF80U110S5C***Cold climate designationAHRI reference: 21727055417.158.50405001.90EPA 4027421
NCDC48CT5****+TDR+ furnace: NF97D090M4C***Cold climate designationAHRI reference: 21727054317.109.00395001.90EPA 4027410

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →