Each efficiency range summarizes published EPA records for XH660E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 81 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 81 / 81 |
| EER2 · BTU/Wh | 11–12 | 81 / 81 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 81 / 81 |
| Cooling capacity · BTU/h | 52,500–54,500 | 81 / 81 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 56,500–60,000 | 81 / 81 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 37,800–39,500 | 81 / 81 |
| Heating capacity at 5°F / −15°C · BTU/h | 30,000–32,600 | 81 / 81 |
| COP at 5°F / −15°C | 2.2–2.38 | 81 / 81 |
| Equipment / loop type | HP - Split System | 81 / 81 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 81 / 81 |
| Compressor staging | Two-stage | 81 / 81 |
| Connected capability | No | 81 / 81 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTU60D5XHS1+TXV+ furnace: RL18130D20MPS1AHRI reference: 217017917 | 15.20 | 8.10 | 31400 | 2.28 | EPA 4571874 → |
CTF60C5CHS1+ furnace: RL18120C20MPS1AHRI reference: 217017892 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4571894 → |
CTF60D5CHS1+JMET18DS2N1AHRI reference: 217017853 | 15.20 | 8.10 | 31200 | 2.30 | EPA 4571924 → |
CTF60C5CHS1+ furnace: RG19080C20MPS1AHRI reference: 217017850 | 15.20 | 8.10 | 32000 | 2.22 | EPA 4571926 → |
CTF60C5CHS1+ furnace: RG19080C16MPS1AHRI reference: 217017841 | 15.20 | 8.00 | 31800 | 2.24 | EPA 4571932 → |
CTF60C5CHS1+JMET16CS2N1AHRI reference: 217017828 | 15.20 | 8.10 | 31400 | 2.28 | EPA 4571943 → |
CTF60C5CHS1+ furnace: RL18120C16MPS1AHRI reference: 217017821 | 15.20 | 8.10 | 31400 | 2.26 | EPA 4571948 → |
CTF60C5CHS1+ furnace: RL18100C20MPS1AHRI reference: 217017816 | 15.20 | 8.10 | 31200 | 2.28 | EPA 4571950 → |
CTF60C5CHS1+ furnace: RG19100C16MPS1AHRI reference: 217017805 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4571960 → |
CTU60D5XHS1+JMET18DS2N1+TXVAHRI reference: 217017803 | 15.20 | 8.10 | 31200 | 2.30 | EPA 4571962 → |
CTF60D5CHS1+JME18D2SN1AHRI reference: 217017777 | 15.20 | 8.10 | 31200 | 2.30 | EPA 4571982 → |
CTF60D5CJS1+ furnace: RG19120D20MPS1AHRI reference: 217017773 | 15.20 | 8.10 | 32400 | 2.32 | EPA 4571985 → |
CTM60D5CJS2+ furnace: RG19120D20MPS1AHRI reference: 218529083 | 15.20 | 8.50 | 32600 | 2.32 | EPA 4647039 → |
CTM60D5CHS2+ furnace: RG19120D20MPS1AHRI reference: 218529029 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4647087 → |
CTM60D5CHS2+ furnace: RL18130D20MPS1AHRI reference: 218529019 | 15.20 | 8.10 | 31400 | 2.28 | EPA 4647097 → |
CTM60C5CHS2+ furnace: RL18120C20MPS1AHRI reference: 218528949 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4647167 → |
CTM60C5CHS2+ furnace: RL18100C16MPS1AHRI reference: 218528939 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4647177 → |
CTM60C5CHS2+ furnace: RG19100C16MPS1AHRI reference: 218528925 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4647191 → |
CTM60C5CHS2+ furnace: RL18080C20MPS1AHRI reference: 218528915 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4647201 → |
CTM60C5CHS2+ furnace: RG19100C20MPS1AHRI reference: 218528893 | 15.20 | 8.10 | 32000 | 2.24 | EPA 4647223 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →