XH660E2S11
LX SERIES · source records, page 2
81 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH660E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 81 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 81 / 81 |
| EER2 · BTU/Wh | 11–12 | 81 / 81 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 81 / 81 |
| Cooling capacity · BTU/h | 52,500–54,500 | 81 / 81 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 56,500–60,000 | 81 / 81 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 37,800–39,500 | 81 / 81 |
| Heating capacity at 5°F / −15°C · BTU/h | 30,000–32,600 | 81 / 81 |
| COP at 5°F / −15°C | 2.2–2.38 | 81 / 81 |
| Equipment / loop type | HP - Split System | 81 / 81 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 81 / 81 |
| Compressor staging | Two-stage | 81 / 81 |
| Connected capability | No | 81 / 81 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM60C5CHS1+ furnace: RL18080C20MPS1AHRI reference: 217018764 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4571497 → |
CTM60C5CHS1+ furnace: RL18100C16MPS1AHRI reference: 217018763 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4571498 → |
CTM60C5CHS1+ furnace: RL18100C20MPS1AHRI reference: 217018762 | 15.20 | 8.10 | 31200 | 2.28 | EPA 4571499 → |
CTM60C5CHS1+ furnace: RL18120C16MPS1AHRI reference: 217018761 | 15.20 | 8.10 | 31400 | 2.26 | EPA 4571500 → |
CTM60C5CHS1+ furnace: RG19080C16MPS1AHRI reference: 217018760 | 15.20 | 7.80 | 31800 | 2.24 | EPA 4571501 → |
CTM60C5CHS1+ furnace: RL18120C20MPS1AHRI reference: 217018759 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4571502 → |
CTM60D5CHS1+ furnace: RL18130D20MPS1AHRI reference: 217018758 | 15.20 | 8.10 | 31400 | 2.28 | EPA 4571503 → |
CTM60C5CHS1+ furnace: RG19080C20MPS1AHRI reference: 217018756 | 15.20 | 8.10 | 32000 | 2.22 | EPA 4571504 → |
CTM60C5CHS1+ furnace: RG19100C16MPS1AHRI reference: 217018755 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4571505 → |
CTM60D5CJS1+ furnace: RG19120D20MPS1AHRI reference: 217018754 | 15.20 | 8.50 | 32600 | 2.32 | EPA 4571506 → |
CTM60D5CHS1+ furnace: RG19120D20MPS1AHRI reference: 217018753 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4571507 → |
CTM60C5CHS1+ furnace: RG19100C20MPS1AHRI reference: 217018752 | 15.20 | 8.10 | 32000 | 2.24 | EPA 4571508 → |
CTF60C5CHS1+ furnace: RG19100C20MPS1AHRI reference: 217018076 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4571752 → |
CTF60D5CHS1+ furnace: RG19120D20MPS1AHRI reference: 217018067 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4571757 → |
CTF60C5CHS1+JME16C2SN1AHRI reference: 217018044 | 15.20 | 8.10 | 31200 | 2.30 | EPA 4571776 → |
CTF60D5CHS1+ furnace: RL18130D20MPS1AHRI reference: 217018029 | 15.20 | 8.10 | 31400 | 2.28 | EPA 4571788 → |
CTU60D5XHS1+JME18D2SN1+TXVAHRI reference: 217018001 | 15.20 | 8.10 | 31200 | 2.30 | EPA 4571810 → |
CTU60D5XHS1+TXV+ furnace: RG19120D20MPS1AHRI reference: 217017954 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4571846 → |
CTF60C5CHS1+ furnace: RL18080C20MPS1AHRI reference: 217017932 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4571863 → |
CTF60C5CHS1+ furnace: RL18100C16MPS1AHRI reference: 217017922 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4571870 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →